MELVILLE, NY ·
OSHA Inspection: ACURA PLUMBING AND HEATING CORP.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ACURA PLUMBING AND HEATING CORP. in OLD COUNTRY RD. - THE KNOLLS, MELVILLE, NY 11746 (NAICS 000000). OSHA activity number 300132891.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACURA PLUMBING AND HEATING CORP.
- Site address
- OLD COUNTRY RD. - THE KNOLLS
- City
- MELVILLE
- State
- NY
- ZIP
- 11746
- Mailing
- 257 4TH AVE., ST. JAMES, NY 11780
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1711
- Employees
- 8
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Apr 11, 1997
- Abate by
- Apr 16, 1997
- Penalty
- Initial $750 · Current $750
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970. The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being pulled into and crushed by the rotating parts of a pipe threading machine: (a)At the worksite - Employees operated a Rigid 300 pipe threading machine activated by a toggle switch that would not automatically shut the machine off if the operator was inadvertently caught up in its rotating parts; on or about 03/20/97. ABATEMENT NOTES: Among other methods, one feasible method to reduce this hazard is to install a properly guarded momentary contact (deadman) foot switch to control the power input into the machine, as stipulated in the American National Standard for pipe tools (ANSI B20B.1- 1982).