Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RODRIGUEZ ELECTRICAL CONTRACTOR

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of RODRIGUEZ ELECTRICAL CONTRACTOR in URB. BORINQUEN GARDEN ESQ. ALAMEDA, RIO PIEDRAS, PR 00927 (NAICS 000000). OSHA activity number 300148301.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rodriguez Electrical Contractor — free Get an email when a new federal OSHA severe-injury report for Rodriguez Electrical Contractor is published. One employer, no account, unsubscribe in one click.
Site address
URB. BORINQUEN GARDEN ESQ. ALAMEDA
City
RIO PIEDRAS
State
PR
ZIP
00927
Mailing
P.O. BOX 3698, GUAYNABO, PR 00970
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1731
Employees
12
Ownership type
A
Industry flags
Construction safety.

6 citations on file for this inspection.

1926.404 C01 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 23, 2001
Abate by
Oct 29, 2001
Penalty
Initial $1,500 · Current $750 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

1926.501 B01

Other-than-serious Gravity 10 5 instances 2 exposed
Issued
Oct 23, 2001
Abate by
Oct 26, 2001
Penalty
Initial $1,500
Recent events (2)
  • — I (O)
  • — Z (S) $1500.00

1926.550 G02

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Oct 23, 2001
Abate by
Oct 26, 2001
Penalty
Initial $1,500
Recent events (2)
  • — I (O)
  • — Z (S) $1500.00

1926.550 G04 IA

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Oct 23, 2001
Abate by
Oct 26, 2001
Penalty
Initial $1,500
Recent events (2)
  • — I (O)
  • — Z (S) $1500.00

1926.550 G04 III

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Oct 23, 2001
Abate by
Oct 26, 2001
Penalty
Initial $1,500
Recent events (2)
  • — I (O)
  • — Z (S) $1500.00

1926.1053 B06

Other-than-serious Gravity 05 1 instance 2 exposed
Issued
Oct 23, 2001
Abate by
Oct 26, 2001
Penalty
Initial $1,050
Recent events (2)
  • — I (O)
  • — Z (S) $1050.00

View Rodriguez Electrical Contractor's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300148301.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.