OSHA Inspection: J & R WELL SERVICE CO. RIG # 2

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J & R WELL SERVICE CO. RIG # 2 in HWY 774 EAST OF REFUGIO, REFUGIO, TX 78377 (NAICS 000000). OSHA activity number 300187606.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & R Well Service CO. RIG # 2 — free Get an email when a new federal OSHA severe-injury report for J & R Well Service CO. RIG # 2 is published. One employer, no account, unsubscribe in one click.
Site address
HWY 774 EAST OF REFUGIO
City
REFUGIO
State
TX
ZIP
78377
Mailing
P.O. BOX 3551, VICTORIA, TX 77903
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1389
Employees
5
Ownership type
A
Industry flags
Manufacturing safety.

5 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Aug 5, 1997
Abate by
Aug 9, 1997
Penalty
Initial $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to a fire and explosion:
Employees were exposed to the hazard of fire and explosion resulting from
an
unknown quantity of flammable gas. The bleed off valve for the annulus of
Section "A" (Bradenhead) had not been opened to assure there was no
accumulation of natural gas in the surface casing prior to beginning well
service
operations. One (1) feasible and acceptable abatement method among others
to
correct the hazards is to assure that the well shall be checked for
pressure and if
pressure is indicated, the operator's authorized person should be
notified: then
proper steps should be taken to remove pressure or to operate safely under
pressure before commencing operations such as specified by API RP 54-92,
Section 5.3.4 page #10. This alleged condition occurred on or about June 5,
1997.
*** Certification and Documentation of Abatement required ***
Recent events (2)
  • — I (S)
  • — Z (S) $1500.00

5(a)(1)

Serious Gravity 10 2 instances 5 exposed
Issued
Aug 5, 1997
Abate by
Aug 10, 1997
Penalty
Initial $1,500 · Current $750 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized
hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to a struck by hazard:
Employees were exposed to the hazard of being struck by a high pressure
flowline due to the failure of securing the flowline.
This occurred on or about June 5, 1997 on J & R Well Service Co. Rig # 2.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard would be to secure the flowline to the ground. Essential
elements of
this procedure would include:
a.Secure the flowline at the end of the flowline and at intermediate
intervals
along the line each 15 to 20 feet.
b.Where chic-san swivel connections are used to make a turn in a flowline
shall be anchored to the ground by means of chains, steel stakes or other
adequate restraint on both ends of the chic-san swivel connection.
c.That employees shall not be permitted to step across and / or on a
pressurized flowline. This would allow for protection of employees who
are working in close proximity to the pressurized flowline.
*** Certification and Documentation of Abatement required ***
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 5, 1997
Abate by
Aug 10, 1997
Penalty
Initial $2,000 · Current $1,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to fire and explosion:
The hazard of being restricted in escape from the monkey board in the
event of
fire or explosion. This occurred on or about June 5, 1997, on J & R Well
Service
Co. Rig # 2. Among other methods, one feasible and acceptable abatement
method to correct this hazard would be installation of a properly rigged
and
secured emergency descent device or other satisfactory means of egress
such as
providing a readily and convenient means of escape from the derrickman's
working platform, such as specified in section 5.7 of API RP54 First
Edition
1992. Essential elements of this procedure would include:
a.Staking out a securely anchored 7/16-inch wire rope escape line attached
to the derrick or mast so as to provide a ready and convenient means of
escape from the derrickman's working platform.
b.The escape line route is to be kept clear of obstructions.
c.A safety device is to be provided to permit fast emergency exit from the
derrickman's working platform to a safe place.
d.The tension on the escape line is to be periodically checked and adjusted
to assure a safe landing and to allow the derrickman to stop twenty (20)
to twenty-five (25) feet from the anchor point.
e.The ground anchor point of the escape line is to be located a minimum
lateral distance from the derrick or mast equal to the height above ground
to the point where the escape line fastened to the derrick or mast.
*** Certification and Documentation of Abatement required ***
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $2000.00

1910.23 C02

Serious Gravity 01 1 instance 1 exposed
Issued
Aug 5, 1997
Abate by
Aug 9, 1997
Penalty
Initial $225 · Current $112 Reduced
Recent events (2)
  • — I (S) $112.00
  • — Z (S) $225.00

1910.179 H02 V

Serious Gravity 02 4 instances 5 exposed
Issued
Aug 5, 1997
Abate by
Aug 10, 1997
Penalty
Initial $300 · Current $100 Reduced
Recent events (2)
  • — I (S) $100.00
  • — Z (S) $300.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300187606.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.