Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ZILOG MANUFACTURING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ZILOG MANUFACTURING in 2601 11TH AVENUE NORTH EXTENSION, NAMPA, ID 83687 (NAICS 000000). OSHA activity number 300208667.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Zilog Manufacturing — free Get an email when a new federal OSHA severe-injury report for Zilog Manufacturing is published. One employer, no account, unsubscribe in one click.
Establishment
ZILOG MANUFACTURING
Site address
2601 11TH AVENUE NORTH EXTENSION
City
NAMPA
State
ID
ZIP
83687
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3674
Employees
400
Ownership type
A

11 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 8 instances 2 exposed
Issued
Aug 12, 1998
Abate by
Sep 8, 1998
Penalty
Initial $4,500 · Current $2,500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to crushing injuries from possible overhead
structure/hoist failure:
(a)Mezzanine:  On or about 29 April 1998, and at times prior thereto, the
hook
for the Budgit 2-ton electric chain hoist was not inspected on a frequent
and
periodic basis in accordance with the American Society of Mechanical
Engineers (ASME) Safety Standards for Cableways, Cranes, Derricks, Hoists,
Hooks, Jacks, and Slings, ASME B30.10a-1996, paragraphs 10-1.2.1.2 and
10-12.1.3
(b)Mezzanine:  On or about 29 April 1998, and at times prior thereto, the
Budgit
2-ton electric chain hoist was not inspected on a frequent and periodic
basis in
accordance with the American Society of Mechanical Engineers (ASME)
Safety Standards for Cableways, Cranes, Derricks, Hoists, Hooks, Jacks, and
Slings, ASME B30.16b-1995, paragraphs 16-2.2.1.2 and 16-2.2.1.3.
(c)Mezzanine:  On or about 29 April 1998, and at times prior thereto, the
overhead support structure for the Budgit 2-ton electric chain hoist was
not
inspected on a frequent and periodic basis in accordance with the American
Society of Mechanical Engineers (ASME) Safety Standards for Overhead and
Gantry Cranes (Top Running Bridge, Single Girder, Underhung Hoist), ASME
B30.17-1992, paragraphs 17-2.1.2 and 17-2.1.3.
(d)Mezzanine:  On or about 29 April 1998, and at times prior thereto, the
supporting structure and the Budgit 2-ton electric chain hoist did not
have a
record documenting that an appropriate rated load test had been performed,
in
accordance with the  America Society of Mechanical Engineers (ASME) Safety
Standards for Overhead and Gantry Cranes (Top Running Bridge, Single
Girder, Underhung Hoist), ASME B30.17-1992, paragraphs 17-2.2.2.
(e)Mezzanine:  On or about 29 April 1998, and at times prior thereto, the
hook
for the CM  Lodestar 1-ton electric chain hoist was not inspected on a
frequent
and periodic basis in accordance with the American Society of Mechanical
Engineers (ASME) Safety Standards for Cableways, Cranes, Derricks, Hoists,
Hooks, Jacks, and Slings, ASME B30.10a-1996, paragraphs 10-1.2.1.2 and
10-12.1.3
(f)Mezzanine:  On or about 29 April 1998, and at times prior thereto, the
CM
Lodestar 1-ton electric chain hoist was not inspected on a frequent and
periodic basis in accordance with the American Society of Mechanical
Engineers (ASME) Safety Standards for Cableways, Cranes, Derricks,
Hoists,Hooks, Jacks, and Slings, ASME B30.16b-1995, paragraphs 16-2.2.1.2
and
16-2.2.1.3.
(g)Mezzanine:  On or about 29 April 1998, and at times prior thereto, the
overhead support structure for the CM Lodestar 1-ton electric chain hoist
was
not inspected on a frequent and periodic basis in accordance with the
American
Society of Mechanical Engineers (ASME) Safety Standards for Overhead and
Gantry Cranes (Top Running Bridge, Single Girder, Underhung Hoist), ASME
B30.17-1992, paragraphs 17-2.1.2 and 17-2.1.3.
(h)Mezzanine:  On or about 29 April 1998, and at times prior thereto, the
supporting structure and the CM Lodestar 1-ton electric chain hoist did not
have a record documenting that an appropriate rated load test had been
performed, in accordance with the  America Society of Mechanical Engineers
(ASME) Safety Standards for Overhead and Gantry Cranes (Top Running
Bridge, Single Girder, Underhung Hoist), ASME Safety Standards for
Overhead and Gantry Cranes (Top Running Bridge, Single Girder, Underhung
Hoist), ASME B30.17-1992, paragraphs 17-2.2.2.
Note:  Abatement certification and supporting documentation are required
for this item.
Recent events (2)
  • — I (S) $2500.00
  • — Z (S) $4500.00

1910.37 K02

Deleted Serious Gravity 03 2 instances 10 exposed
Issued
Aug 12, 1998
Abate by
Aug 17, 1998
Penalty
Initial $1,875 · Current $1,875
Recent events (2)
  • — I (S) $1875.00
  • — Z (S) $1875.00

1910.37 Q01

Deleted Serious Gravity 03 2 instances 10 exposed
Issued
Aug 12, 1998
Abate by
Aug 24, 1998
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 C02

Serious Gravity 03 1 instance 1 exposed
Issued
Aug 12, 1998
Abate by
Aug 24, 1998
Penalty
Initial $1,875 · Current $1,000 Reduced
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $1875.00

1910.146 C03

Serious Gravity 03 1 instance 1 exposed
Issued
Aug 12, 1998
Abate by
Aug 24, 1998
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 D14

Deleted Serious Gravity 03 1 instance 4 exposed
Issued
Aug 12, 1998
Abate by
Sep 8, 1998
Penalty
Initial $1,875 · Current $1,875
Recent events (2)
  • — I (S) $1875.00
  • — Z (S) $1875.00

1910.146 E06

Other-than-serious Gravity 03 1 instance 1 exposed
Issued
Aug 12, 1998
Abate by
Sep 8, 1998
Recent events (2)
  • — I (O)
  • — Z (S)

1910.146 K03 I

Serious Gravity 03 2 instances 2 exposed
Issued
Aug 12, 1998
Abate by
Aug 31, 1998
Penalty
Initial $1,875 · Current $1,875
Recent events (2)
  • — I (S) $1875.00
  • — Z (S) $1875.00

1910.219 C02 I

Serious Gravity 10 5 instances 2 exposed
Issued
Aug 12, 1998
Abate by
Sep 8, 1998
Penalty
Initial $4,500 · Current $3,500 Reduced
Recent events (2)
  • — I (S) $3500.00
  • — Z (S) $4500.00

1910.219 D01

Deleted Serious Gravity 03 1 instance 2 exposed
Issued
Aug 12, 1998
Abate by
Sep 8, 1998
Penalty
Initial $1,875 · Current $1,875
Recent events (2)
  • — I (S) $1875.00
  • — Z (S) $1875.00

1910.219 E03 I

Deleted Serious Gravity 03 1 instance 2 exposed
Issued
Aug 12, 1998
Abate by
Sep 8, 1998
Recent events (2)
  • — I (S)
  • — Z (S)

View Zilog Manufacturing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300208667.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.