REHOBOTH, MA —
OSHA Inspection: ROMAC MECHANICAL CONTRACTORS, INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROMAC MECHANICAL CONTRACTORS, INCORPORATED in 330 WINTHROP STREET (REAR), REHOBOTH, MA 02769 (NAICS 000000). OSHA activity number 300342086.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROMAC MECHANICAL CONTRACTORS, INCORPORATED
- Site address
- 330 WINTHROP STREET (REAR)
- City
- REHOBOTH
- State
- MA
- ZIP
- 02769
- Mailing
- 385 PLEASENT STREET BLDG. #11, FALL RIVER, MA 02722
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1711
- Employees
- 22
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 23, 1997
- Abate by
- Sep 30, 1997
- Penalty
- Initial $300 · Current $150 Reduced
General-duty citation text
Section 5 (a)(1) of the occupational safety and health act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: A power driven threading machine with an unguarded rotating pipe that could catch clothing or extremities while making the operator helpless to shut power off. Among other methods, one feasible and acceptable method to correct this hazard would be installing a momentary contact device as stated in the American National Standard Institute for pipe tools,(ANSI) B208-1982 paragraph 4.4. Employees were operating a power driven threading machine without a momentary contact device, in the hallway outside of the boiler room.r
Recent events (2)
- — I (S) $150.00
- — Z (S) $300.00
1926.403 B02
- Issued
- Sep 23, 1997
- Abate by
- Sep 30, 1997
- Penalty
- Initial $300 · Current $150 Reduced
Recent events (2)
- — I (S) $150.00
- — Z (S) $300.00
1926.404 B01 I
- Issued
- Sep 23, 1997
- Abate by
- Sep 30, 1997
- Penalty
- Initial $300 · Current $150 Reduced
Recent events (2)
- — I (S) $150.00
- — Z (S) $300.00
More inspections at Romac Mechanical Contractors, Incorporated
View Romac Mechanical Contractors, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300342086.