Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: A & S ELECTRIC INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of A & S ELECTRIC INC in 1200 4TH AVENUE NORTH, NASHVILLE, TN 37208 (NAICS 000000). OSHA activity number 300458668.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & S Electric INC for free Get an email when a new federal OSHA severe-injury report for A & S Electric INC is published. One employer, no account, unsubscribe in one click.
Establishment
A & S ELECTRIC INC
Site address
1200 4TH AVENUE NORTH
City
NASHVILLE
State
TN
ZIP
37208
Mailing
80 CLEVELAND STREET, NASHVILLE, TN 37207
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1731
Employees
75
Ownership type
Private (A)
Industry flags
Construction safety.

2 citations on file for this inspection.

503010501

Serious 2 instances 1 exposed
Issued
Jan 29, 1999
Abate by
Jul 15, 1999
Penalty
Initial $1,600 · Current $1,600
T.C.A. 50-3-105(1):  The employer did not furnish employment and a place
of employment
which were free from recognized hazards that were causing or likely to
cause death or serious
physical harm to employees in that employees were exposed to the operation
and use of defective
aerial lift equipment which upon failure could result in serious injury
and or death from falls
from elevations.
In that, aerial lift equipment in use had the following defects:
1) The bucket on vehicle #30 was cracked down two sides of the bucket
which could create a
bucket failure.  The bucket also had a missing piece which had been broken
off the top section
of the bucket.
2) Vehicle #28 had a loose operator control box, a damaged wire cable on
the boom, two
hydraulic hose leaks were observed, and a leak in the cylinder seal.
Among others, one method of feasible abatement for these defects would be
to replace the
damaged bucket, replace the operator control box, the damaged wire cable,
and perform
appropriate maintenance and repairs to eliminate the leaking hydraulic
hoses/seal.
Recent events (2)
  • · P (S) $1600.00
  • · Z (S) $1600.00

1926.453 B02 IX

Serious 1 instance 1 exposed
Issued
Jan 29, 1999
Abate by
Jul 15, 1999
Penalty
Initial $800 · Current $800
Recent events (2)
  • · P (S) $800.00
  • · Z (S) $800.00

View A & S Electric INC's full OSHA safety record →