Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLORIDA ATLANTIC CONTRACTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FLORIDA ATLANTIC CONTRACTORS, INC. in 1160 W. 10TH ST., RIVIERA BEACH, FL 33404 (NAICS 000000). OSHA activity number 300496247.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Florida Atlantic Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for Florida Atlantic Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1160 W. 10TH ST.
City
RIVIERA BEACH
State
FL
ZIP
33404
Mailing
3300 S. CONGRESS AVE.- #23, BOYNTON BEACH, FL 33426
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1791
Employees
60
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 17, 1998
Abate by
Apr 23, 1998
Penalty
Initial $3,000 · Current $1,750 Reduced
Section 5(A)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish to employees employment and a place of
employment which were
free from recognized hazards that were causing or likely to cause death or
serious physical harm
to employees in that:
On or about 12/02/97 employees erecting a steel beam between columns C & D
were exposed
to the hazards of falls or being struck by falling beam due to the lack of
temporary bracing or
other securing means during the erection process. Employees were in the
process of making a
double connection without ensuring the beam was secured and supported.
Among other methods, feasible and acceptable abatement methods to correct
this hazard
include, but are not limited to:
Establishment of work practice which assure the stability of the structure
through the use of
adequate temporary bracing, or other means where needed such as:
(1) Support the load by the crane.
(2) Shore post the beam from the ground level.
(3) Puddle weld or welding clips.
(4) Use a come-a- long to secure the beam to the column until the
connection is made.
(5) Instruct employees not to work under a load.
(6) Consult the structural detailer and fabricator concerning the
provisions for a seat lug or
flange length extension on one of the beams and a corresponding bolt hole
in the web of the
column as required by ANSI A10.13 1989 section 9.5.
PLEASE NOTE:  CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS
REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — J (S) $1750.00
  • — Z (S) $3000.00

View Florida Atlantic Contractors, INC.'s full OSHA safety record →