SPRINGFIELD, MA —
OSHA Inspection: HBA CAST PRODUCTS CO., INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of HBA CAST PRODUCTS CO., INC. in 262 LIBERTY ST., SPRINGFIELD, MA 01101 (NAICS 000000). OSHA activity number 300506367.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HBA CAST PRODUCTS CO., INC.
- Site address
- 262 LIBERTY ST.
- City
- SPRINGFIELD
- State
- MA
- ZIP
- 01101
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3365
- Employees
- 165
- Ownership type
- A
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 22, 1999
- Abate by
- Sep 30, 2000
- Penalty
- Initial $1,875 · Current $938 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees engaged in aluminum processing and finishing operations such grinding, wheelabrating, sawing, and regular maintenance of the processing equipment's dust collection systems were exposed to potential fire and explosion hazards posed by the generation of fine metallic dusts : SPECIFICALLY , EMPLOYEES WERE EXPOSED TO THE FOLLOWING FIRE AND EXPLOSION HAZARDS: a) GRINDING AREA: THE ROTOCLONE DRY TYPE DUST COLLECTOR WAS NOT LOCATED OUTSIDE THE BUILDING. b) GRINDING AREA: THE BLOWER FOR DRAWING THE DUST LADEN AIR INTO THE ROTOCLONE DUST COLLECTOR WAS NOT LOCATED ON THE CLEAN AIR SIDE OF THE ROTOCLONE'S DRY TYPE DUST COLLECTOR. c) GRINDING AREA, GE HUB DEPARTMENT & PERMANENT MOLD DEPARTMENT: DUST FROM GRINDING AND SHOT BLASTING OPERATIONS WAS NOT REMOVED FROM THE DRY TYPE COLLECTORS AT LEAST ONCE DAILY. d) GE HUB DEPT: THE DRY TYPE DUST COLLECTOR SERVING THE WHEELABRATOR A TABLE MODEL 70-AC SN 102414 BLAST CLEANER, WAS NOT LOCATED OUTSIDE THE BUILDING. e) GE HUB DEPARTMENT; THE CARBORUNDUM DRY TYPE DUST COLLECTOR, SN # 73.242.1.02.01.400.CN2, SERVING THE REBUILT WHEELABRATOR TUMBLASTER, MODEL A121491 WAS NOT INSTALLED OUTSIDE THE BUILDING. f) PERMANENT MOLD DEPARTMENT: THE AMERICAN DUST TUBE DRY TYPE DUST COLLECTOR SERVING THE WHEELABRATOR TUMBLASTER , SERIAL NO. A 59470, WAS NOT INSTALLED OUTSIDE THE BUILDING. g) THE AREAS AROUND THE DRY TYPE DUST COLLECTORS IN THE GE HUB, GRINDING AND THE PERMANENT MOLD DEPARTMENT WERE NOT POSTED WITH CAUTION SIGNS WARNING " THIS DUST COLLECTOR CAN CONTAIN EXPLOSIBLE DUST" h) GRINDING DEPARTMENT; THE DUST HOODS SERVICING GRINDING MACHINES IN THE GRINDING DEPARTMENT WERE NOT PROVIDED WITH PLACARDS WARNING USERS "ALUMINUM METALS ONLY- FIRE OR EXPLOSION CAN RESULT WITH OTHER METALS." AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THESE HAZARDS WOULD BE THE FOLLOWING ; 1) LOCATE ALL THREE WHEELABRATOR'S DUST COLLECTION SYSTEMS OUTSIDE THE BUILDING OR SEGREGATE IT FROM THE PROCESSING AREAS AS RECOMMENDED BY NFPA 651, 1998 EDITION , STANDARD FOR THE MACHINING AND FINISHING OF ALUMINUM AND THE PRODUCTION AND HANDLING OF ALUMINUM POWDERS, CHAPTER 4. 2) REPLACE, MODIFY OR UPGRADE THE ROTOCLONE'S DUST COLLECTION SYSTEM SERVING THE GRINDING DEPARTMENT SO THAT THE BLOWER DRAWING THE DUST LADEN AIR FROM THE GRINDERS IS SITUATED ON THE CLEAN SIDE OF THE DRY TYPE COLLECTOR, AS RECOMMENDED BY NFPA 651 CHAPTER 4. 3) EVALUATE ALL EXISTING VENTILATION EQUIPMENT FOR CONFORMANCE WITH NFPA 651 CHAPTER 4 4) ESTABLISH REGULAR HOUSEKEEPING PRACTICES, AS RECOMMENDED BY NFPA 651 CHAPTER 5 TO PREVENT ACCUMULATION OF FINE METAL DUSTS. 5) POST AREAS AND EQUIPMENT THAT POSE FIRE AND EXPLOSION HAZARDS WITH WARNING SIGNS AS RECOMMENDED BY NFPA 651 CHAPTER 4. 6) ESTABLISH A DAILY DUST COLLECTOR EMPTYING SCHEDULE AS RECOMMENDED BY NFPA 651 CHAPTER 4, 7) ESTABLISH AN EMPLOYEE TRAINING PROGRAM WHICH WOULD INCLUDE THE FOLLOWING: i) Training in the safe handling of aluminum dusts and specific requirements applicable to the work environment to control or eliminate the fire and explosion hazards. ii) Procedures to be followed in case of equipment or process failure that may result in fire or explosion, iii) Develop operating procedures which are reviewed at least once per year and after every process change. 8) DESIGN WORK AREA INTERIORS AND EQUIPMENT TO BE SMOOTH AND EASY TO CLEAN. 9) ELIMINATE ALL SOURCES OF IGNITION INCLUDING SMOKING, OPEN FLAMES, LIGHTS AND STATIC ELECTRICITY. 10) REDESIGN EQUIPMENT SUCH AS GRINDER HOODS, AND OTHER DUST HANDLING OPERATIONS SUCH AS COLLECTOR EMPTYING TO BE AS DUST TIGHT AS POSSIBLE.
Recent events (3)
- — P (S) $937.50
- — A (S) $937.50
- — Z (S) $1875.00
5(a)(1)
- Issued
- Jul 6, 1999
- Abate by
- Jan 18, 2001
- Penalty
- Initial $1,500 · Current $750 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to burns from the accidental ignition of natural gas due to improper use of flexible hose connectors providing fuel gas/air mixture to portable die heating burners. PERMANENT MOLD DEPARTMENT: PORTABLE DIE HEATING BURNERS UTILIZING PRESSURIZED NATURAL GAS/AIR MIX WERE CONNECTED TO TWO (2) GAS MIXING MACHINES WITH FLEXIBLE CONNECTORS WHICH HAD THE FOLLOWING RECOGNIZED HAZARDS: a)FLEXIBLE CONNECTIONS WERE IN EXCESS OF MINIMUM PRACTICAL LENGTHS. b) FLEXIBLE CONNECTORS HAD EXTENSIVE PHYSICAL DAMAGE AND HAD NOT BEEN REMOVED FROM SERVICE. c) FLEXIBLE CONNECTIONS WERE NOT CONNECTED TO SUPPLY MANIFOLDS AND BURNERS WITH APPROVED CLAMPS OR CONNECTION DEVICES, d) SHUT OFF VALVES WERE NOT LOCATED WITHIN 6 FEET OF THE EQUIPMENT SERVED BY THE GAS. e) IN SOME INSTANCES, FLEXIBLE CONNECTORS WERE INSTALLED DIRECTLY IN THE BURNER'S FLAME, AND f) APPROVED AUTOMATIC FIRECHECKS WERE NOT INSTALLED UPSTREAM AND AS CLOSE AS PRACTICAL TO BURNER INLETS. AMONG OTHER METHODS ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THESE HAZARDS WOULD BE TO ENSURE THAT ALL NATURAL GAS PIPING AND FLEXIBLE CONNECTION SYSTEMS MEET SPECIFICATIONS SET FORTH BY THE NATIONAL FUEL GAS CODE, ANSI Z223.1- 1996, NFPA 54-1996 OR OTHER NATIONALLY RECOGNIZED AUTHORITY.
Recent events (3)
- — P (S) $750.00
- — I (S) $750.00
- — Z (S) $1500.00
5(a)(1)
- Issued
- Jul 6, 1999
- Abate by
- Jul 9, 1999
- Penalty
- Initial $1,875
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of rapidly expanding steam vapor/molten metal explosion. a) CENTRAL MELT/LARGE DIECAST DEPARTMENT: EMPLOYEES WORKING IN THE FOUNDRY IN THE VICINITY OF THE CENTRAL FURNACE AND DIECASTERS # 23, 24 AND 25 WERE EXPOSED TO THE HAZARD OF AN EXPLOSION BECAUSE POOLS OF WATER WERE ALLOWED TO ACCUMULATE BENEATH THE THREE LARGE DIECAST MACHINES. MOLTEN METAL ACCIDENTLY SPILLING DURING ANY PART OF THE OPERATION COULD ENTRAP THE WATER THEREBY CAUSING AN EXPLOSION. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD WOULD BE TO REPAIR ALL WATER LEAKS IN THE LARGE DIECASTERS COOLING SYSTEMS THAT IS RESULTING IN THE STANDING POOLS OF WATER UNDER AND AROUND THE DIECASTERS, ESTABLISH A MORE EFFECTIVE PREVENTIVE MAINTENANCE PROGRAM FOR THE DIECASTERS TO MINIMIZE FUTURE WATER LEAKS AND IMPLEMENT A ZERO TOLERANCE FOR THE PRESENCE OF STANDING WATER IN ALL MOLTEN METAL HANDLING AREAS.
Recent events (2)
- — Z (S) $1875.00
- — I (O)
1910.22 A01
- Issued
- Jul 6, 1999
- Abate by
- Jul 16, 1999
- Penalty
- Initial $1,875 · Current $938 Reduced
Recent events (2)
- — I (S) $938.00
- — Z (S) $1875.00
1910.157 D06
- Issued
- Jul 6, 1999
- Abate by
- Jul 23, 1999
1910.23 A04
- Issued
- Jul 6, 1999
- Abate by
- Sep 8, 1999
- Penalty
- Initial $1,875 · Current $938 Reduced
Recent events (2)
- — I (S) $938.00
- — Z (S) $1875.00
1910.23 C01
- Issued
- Jul 6, 1999
- Abate by
- Sep 8, 1999
Recent events (2)
- — I (S)
- — Z (S)
1910.212 A01
- Issued
- Jul 6, 1999
- Abate by
- Aug 8, 1999
- Penalty
- Initial $1,875 · Current $938 Reduced
Recent events (2)
- — I (S) $938.00
- — Z (S) $1875.00
1910.215 A02
- Issued
- Jul 6, 1999
- Abate by
- Aug 8, 1999
1910.215 B09
- Issued
- Jul 6, 1999
- Abate by
- Aug 8, 1999
Recent events (2)
- — I (S)
- — Z (S)
1910.303 G02 I
- Issued
- Jul 6, 1999
- Abate by
- Jul 9, 1999
- Penalty
- Initial $1,875 · Current $938 Reduced
Recent events (2)
- — I (S) $938.00
- — Z (S) $1875.00
1910.305 B02
- Issued
- Jul 6, 1999
- Abate by
- Jul 16, 1999
- Penalty
- Initial $1,875 · Current $938 Reduced
Recent events (2)
- — I (S) $938.00
- — Z (S) $1875.00
More inspections at HBA Cast Products CO., INC.
View HBA Cast Products CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300506367.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.