RHOME, TX —
OSHA Inspection: ENERGY SERVICE COMPANY OF BOWIE INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of ENERGY SERVICE COMPANY OF BOWIE INC. in PIONEER RD & PIONEER PKWY, RHOME, TX 76078 (NAICS 000000). OSHA activity number 300517927.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENERGY SERVICE COMPANY OF BOWIE INC.
- Site address
- PIONEER RD & PIONEER PKWY
- City
- RHOME
- State
- TX
- ZIP
- 76078
- Mailing
- P.O. BOX 1300, BOWIE, TX 76230
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1389
- Employees
- 70
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 14, 1998
- Abate by
- Aug 14, 1998
- Penalty
- Initial $2,500 · Current $2,500
General-duty citation text
Section 5(a)(1) The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Employees of Energy Service Company, a sub contractor to Mitchell Energy Corporation, were involved in an oil rig fire that occurred on May 6, 1998. The employees were required to perform work at the well head, Carl V. Cheves #2, located in East Risch (Caddo Congl.) field, Wise County, Texas. The employees were exposed to the hazards of natural gas/fluid (oil) igniting causing a fire and/or explosion, for they were not provided protection that ensured all vehicles, including but not limited to transport, rig, company and hot oilers, to be properly positioned away from the well to remove potential ignition sources. Among methods of abatement, one feasible and acceptable method to abate these conditions would be for the employer to enforce his own policies and/or abide by the American Petroleum Institute Recommended Practices #54; or the Association of Energy Service Companies, which the employer has adopted. The "Recommended" Industry practice is to position all vehicles (Company trucks as well as Hot Oil trucks) at least 100 feet from the well bore.
Recent events (2)
- — I (S) $2500.00
- — Z (S) $2500.00
5(a)(1)
- Issued
- Aug 14, 1998
- Abate by
- Aug 14, 1998
- Penalty
- Initial $2,500 · Current $2,500
General-duty citation text
Section 5(a)(1) The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) On May 6, 1998, a crew of 4, employed by Energy Service Company, a sub contractor of Mitchell Energy Corporation, were working at the Carl V. Cheves #2 well, when oil and gas spewing from the BOP caught fire. The employer had developed a worksite safety and health program, but did not implement this program. (b) On May 6, 1998, a crew of 4 from Energy Service Company arrived at the Carl V. Cheves, #2 well, located in East Risch (Caddo Congl.) field, Wise County, Texas. The crew was pulling tubing and installing a Guiberson 6" 900 series A1 manual type BOP. The crew and/or the rig operator, did not perform a funtional test or a pressure test on the BOP prior to using it. The well started spewing oil and gas from the BOP, the crew was attempting to close the BOP, when the oil and gas ignited. Among methods of abatement, one feasible and acceptable method to abate these conditions: a) Employer needs to develop and implement methods to ensure all employees are familiar and knowledgeable in the companies safe work practices and procedures. b) Employer needs to enforce his own policies and/or abide by the "recommended guidelines/practices" that are set from the American Petroleum Institute, #54 or from the Association of Energy Service Companies.
Recent events (2)
- — I (S) $2500.00
- — Z (S) $2500.00
More inspections at Energy Service Company of Bowie INC.
View Energy Service Company of Bowie INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300517927.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.