Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: VICTOR EQUIPMENT COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VICTOR EQUIPMENT COMPANY in 2800 AIRPORT ROAD, DENTON, TX 76205 (NAICS 000000). OSHA activity number 300519592.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Victor Equipment Company for free Get an email when a new federal OSHA severe-injury report for Victor Equipment Company is published. One employer, no account, unsubscribe in one click.
Site address
2800 AIRPORT ROAD
City
DENTON
State
TX
ZIP
76205
Mailing
P. O. BOX 1007, DENTON, TX 76202
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3548
Employees
650
Ownership type
Private (A)

10 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 26, 1999
Abate by
Apr 14, 1999
Penalty
Initial $5,000 · Current $2,500 Reduced
SECTION 5(A)(1)
The Employer did not furnish employment and a place of employment which
was free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees:
At the Oxygen-Fill Station, in Department 421 in the northeast corner of
the plant,
employees were exposed to an explosion hazard when filling medical oxygen
cylinders. The
system was not equipped with emergency shut-off valves and an alarm system
in order to
abort or shut down the system in case of an emergency.
On September 23, 1998, three employees suffered burns when oxygen entered
the vacuum
pump resulting in an explosion.
FEASIBLE MEANS OF ABATEMENT:
One feasible means of abatement is to install emergency shut-off valves on
the oxygen line
and to install a visible or an audible alarm in case of an emergency and
the line had to be
shut off.
Recent events (2)
  • · I (S) $2500.00
  • · Z (S) $5000.00

5(a)(1)

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Feb 26, 1999
Abate by
Apr 14, 1999
Penalty
Initial $5,000 · Current $5,000
SECTION 5(A)(1)
The Employer did not furnish employment and a place of employment which
was free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees:
On September 23, 1998, the oxygen fill station located in the northeast
corner of the
plant in Department 421 where three employees suffered burns when oxygen
entered the
vacuum pump resulting in an explosion.  The Oxygen-fill station was not
isolated from other
areas of the plant.
FEASIBLE MEANS OF ABATEMENT:
One feasible means of abatement is to install the oxygen fill station in a
room by itself with
the appropriate hazard warnings posted and having at least two means of
egress.
Recent events (2)
  • · I (S) $5000.00
  • · Z (S) $5000.00

1910.22 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 26, 1999
Abate by
Apr 14, 1999
Penalty
Initial $5,000 · Current $2,500 Reduced
Recent events (2)
  • · I (S) $2500.00
  • · Z (S) $5000.00

1910.132 A

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 26, 1999
Abate by
Apr 14, 1999
Penalty
Initial $5,000 · Current $2,500 Reduced
Recent events (2)
  • · I (S) $2500.00
  • · Z (S) $5000.00

1910.145 C03

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Feb 26, 1999
Abate by
Apr 14, 1999
Penalty
Initial $5,000
Recent events (2)
  • · I (O)
  • · Z (S) $5000.00

1910.1200 G10

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 26, 1999
Abate by
Apr 14, 1999
Penalty
Initial $5,000 · Current $2,500 Reduced
Recent events (2)
  • · I (S) $2500.00
  • · Z (S) $5000.00

5(a)(1)

Deleted Willful Gravity 10 1 instance 3 exposed
Issued
Feb 26, 1999
Abate by
Apr 14, 1999
Penalty
Initial $30,000 · Current $30,000
SECTION 5(A)(1)
The Employer did not furnish employment and a place of employment which
was free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees:
At the Oxygen-Fill Station, in Department 421 in the northeast corner of
the plant,
employees were exposed to an explosion hazard when filling medical oxygen
cylinders. The
vacuum pump was not equipped with a relief valve or any other type of
safety devices to
prevent oxygen from entering the pump and creating an explosive mixture
with the pump oil.
The employer did not follow the guidelines as outlined in NFPA 99C 1996 or
as
per industry
practice.  The employer did not follow their own requirements as was
required in the
employers "USP Oxygen Fill Process Validation Protocol" that was signed by
management
on September 4, 1998.
On September 23, 1998, three employees suffered burns when oxygen entered
the vacuum
pump resulting in an explosion.
FEASIBLE MEANS OF ABATEMENT:
One feasible means of abatement is to install a relief valve on the oxygen
line to prevent the
oxygen from entering the vacuum pump and creating an explosive mixture.
Recent events (2)
  • · I (W) $30000.00
  • · Z (W) $30000.00

5(a)(1)

Deleted Willful Gravity 10 1 instance 3 exposed
Issued
Feb 26, 1999
Abate by
Apr 14, 1999
Penalty
Initial $30,000 · Current $30,000
SECTION 5(a)(1)
The employer did not furnish employment and a place of employment which
was free from
recognized hazards that were causing or likely to cause death or serious
physical
harm to
employees:
At the Oxygen-Fill Station, Department 421 in the northeast corner of the
plant, employees
were exposed to an explosion hazard when filling medical oxygen cylinders.
The system
being operated, was not equipped with interlocks to prevent the operator
from introducing
high pressure oxygen to the vacuum pump which contained combustible oil.
On September 23, 1998, three employees suffered burns when oxygen entered
the vacuum
pump resulting in an explosion.
FEASIBLE MEANS OF ABATEMENT:
One feasible means of abatement is to installed interlocks on the control
valves to prevent the
opening of one or more valves at a time to keep oxygen from entering the
vacuum pump.
Recent events (2)
  • · I (W) $30000.00
  • · Z (W) $30000.00

5(a)(1)

Willful Gravity 10 1 instance 3 exposed
Issued
Feb 26, 1999
Abate by
Apr 14, 1999
Penalty
Initial $30,000
Recent events (2)
  • · I (W)
  • · Z (W) $30000.00

5(a)(1)

Willful Gravity 10 1 instance 3 exposed
Issued
Feb 26, 1999
Abate by
Apr 14, 1999
Penalty
Initial $30,000 · Current $30,000
SECTION 5(a)(1)
The employer did not furnish employment and a place of employment which
was free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees:
At the Oxygen-Fill Station, Department 421 in the northeast corner of the
plant, employees
were exposed to an explosion hazard when filling medical oxygen cylinders.
The system
being operated, was not equipped with interlocks to prevent the operator
from introducing
high pressure oxygen to the vacuum pump which contained combustible oil.
On September 23, 1998, three employees suffered burns when oxygen entered
the vacuum
pump resulting in an explosion.
FEASIBLE MEANS OF ABATEMENT:
One feasible means of abatement is to installed interlocks on the control
valves to prevent the
opening of one or more valves at a time to keep oxygen from entering the
vacuum pump.
Recent events (2)
  • · I (W) $30000.00
  • · Z (W) $30000.00

View Victor Equipment Company's full OSHA safety record →