DENTON, TX ·
OSHA Inspection: VICTOR EQUIPMENT COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of VICTOR EQUIPMENT COMPANY in 2800 AIRPORT ROAD, DENTON, TX 76205 (NAICS 000000). OSHA activity number 300519592.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VICTOR EQUIPMENT COMPANY
- Site address
- 2800 AIRPORT ROAD
- City
- DENTON
- State
- TX
- ZIP
- 76205
- Mailing
- P. O. BOX 1007, DENTON, TX 76202
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3548
- Employees
- 650
- Ownership type
- Private (A)
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 26, 1999
- Abate by
- Apr 14, 1999
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
SECTION 5(A)(1) The Employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: At the Oxygen-Fill Station, in Department 421 in the northeast corner of the plant, employees were exposed to an explosion hazard when filling medical oxygen cylinders. The system was not equipped with emergency shut-off valves and an alarm system in order to abort or shut down the system in case of an emergency. On September 23, 1998, three employees suffered burns when oxygen entered the vacuum pump resulting in an explosion. FEASIBLE MEANS OF ABATEMENT: One feasible means of abatement is to install emergency shut-off valves on the oxygen line and to install a visible or an audible alarm in case of an emergency and the line had to be shut off.
Recent events (2)
- · I (S) $2500.00
- · Z (S) $5000.00
5(a)(1)
- Issued
- Feb 26, 1999
- Abate by
- Apr 14, 1999
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
SECTION 5(A)(1) The Employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: On September 23, 1998, the oxygen fill station located in the northeast corner of the plant in Department 421 where three employees suffered burns when oxygen entered the vacuum pump resulting in an explosion. The Oxygen-fill station was not isolated from other areas of the plant. FEASIBLE MEANS OF ABATEMENT: One feasible means of abatement is to install the oxygen fill station in a room by itself with the appropriate hazard warnings posted and having at least two means of egress.
Recent events (2)
- · I (S) $5000.00
- · Z (S) $5000.00
1910.22 A01
- Issued
- Feb 26, 1999
- Abate by
- Apr 14, 1999
- Penalty
- Initial $5,000 · Current $2,500 Reduced
Recent events (2)
- · I (S) $2500.00
- · Z (S) $5000.00
1910.132 A
- Issued
- Feb 26, 1999
- Abate by
- Apr 14, 1999
- Penalty
- Initial $5,000 · Current $2,500 Reduced
Recent events (2)
- · I (S) $2500.00
- · Z (S) $5000.00
1910.145 C03
- Issued
- Feb 26, 1999
- Abate by
- Apr 14, 1999
- Penalty
- Initial $5,000
Recent events (2)
- · I (O)
- · Z (S) $5000.00
1910.1200 G10
- Issued
- Feb 26, 1999
- Abate by
- Apr 14, 1999
- Penalty
- Initial $5,000 · Current $2,500 Reduced
Recent events (2)
- · I (S) $2500.00
- · Z (S) $5000.00
5(a)(1)
- Issued
- Feb 26, 1999
- Abate by
- Apr 14, 1999
- Penalty
- Initial $30,000 · Current $30,000
General-duty citation text
SECTION 5(A)(1) The Employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: At the Oxygen-Fill Station, in Department 421 in the northeast corner of the plant, employees were exposed to an explosion hazard when filling medical oxygen cylinders. The vacuum pump was not equipped with a relief valve or any other type of safety devices to prevent oxygen from entering the pump and creating an explosive mixture with the pump oil. The employer did not follow the guidelines as outlined in NFPA 99C 1996 or as per industry practice. The employer did not follow their own requirements as was required in the employers "USP Oxygen Fill Process Validation Protocol" that was signed by management on September 4, 1998. On September 23, 1998, three employees suffered burns when oxygen entered the vacuum pump resulting in an explosion. FEASIBLE MEANS OF ABATEMENT: One feasible means of abatement is to install a relief valve on the oxygen line to prevent the oxygen from entering the vacuum pump and creating an explosive mixture.
Recent events (2)
- · I (W) $30000.00
- · Z (W) $30000.00
5(a)(1)
- Issued
- Feb 26, 1999
- Abate by
- Apr 14, 1999
- Penalty
- Initial $30,000 · Current $30,000
General-duty citation text
SECTION 5(a)(1) The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: At the Oxygen-Fill Station, Department 421 in the northeast corner of the plant, employees were exposed to an explosion hazard when filling medical oxygen cylinders. The system being operated, was not equipped with interlocks to prevent the operator from introducing high pressure oxygen to the vacuum pump which contained combustible oil. On September 23, 1998, three employees suffered burns when oxygen entered the vacuum pump resulting in an explosion. FEASIBLE MEANS OF ABATEMENT: One feasible means of abatement is to installed interlocks on the control valves to prevent the opening of one or more valves at a time to keep oxygen from entering the vacuum pump.
Recent events (2)
- · I (W) $30000.00
- · Z (W) $30000.00
5(a)(1)
- Issued
- Feb 26, 1999
- Abate by
- Apr 14, 1999
- Penalty
- Initial $30,000
Recent events (2)
- · I (W)
- · Z (W) $30000.00
5(a)(1)
- Issued
- Feb 26, 1999
- Abate by
- Apr 14, 1999
- Penalty
- Initial $30,000 · Current $30,000
General-duty citation text
SECTION 5(a)(1) The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: At the Oxygen-Fill Station, Department 421 in the northeast corner of the plant, employees were exposed to an explosion hazard when filling medical oxygen cylinders. The system being operated, was not equipped with interlocks to prevent the operator from introducing high pressure oxygen to the vacuum pump which contained combustible oil. On September 23, 1998, three employees suffered burns when oxygen entered the vacuum pump resulting in an explosion. FEASIBLE MEANS OF ABATEMENT: One feasible means of abatement is to installed interlocks on the control valves to prevent the opening of one or more valves at a time to keep oxygen from entering the vacuum pump.
Recent events (2)
- · I (W) $30000.00
- · Z (W) $30000.00
More inspections at Victor Equipment Company
View Victor Equipment Company's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 300519592.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.