ROCKFORD, IL ·
OSHA Inspection: ECLIPSE COMBUSTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ECLIPSE COMBUSTION, INC. in 1665 ELMWOOD RD., ROCKFORD, IL 61103 (NAICS 000000). OSHA activity number 300583002.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ECLIPSE COMBUSTION, INC.
- Site address
- 1665 ELMWOOD RD.
- City
- ROCKFORD
- State
- IL
- ZIP
- 61103
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3433
- Employees
- 220
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 22, 1996
- Abate by
- Sep 24, 1996
- Penalty
- Initial $1,875 · Current $1,313 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to:The hazard of rotating pipe. Employees using the Rigid Pipe Threader, Model 535, Serial #317826, were exposed to rotating pipe that was being threaded by the machine. No method was provided to effectively shut off the power to the machine, other than the motor control switch, which may be outside the reach of the operator. Among other methods, one feasible and acceptable method to correct this hazard would be to provide a foot switch for this machine, as recommended by the manufacturer in their foot switch policy, issued to all their distributors 10/26/87 and re-issued 2/2/93.ed
Recent events (2)
- · I (S) $1312.50
- · Z (S) $1875.00
1910.147 C04 II
- Issued
- Aug 22, 1996
- Abate by
- Oct 24, 1996
Recent events (2)
- · I (O)
- · Z (O)
1910.179 G01 V
- Issued
- Aug 22, 1996
- Abate by
- Aug 27, 1996
Recent events (2)
- · I (O)
- · Z (O)
1910.213 H04
- Issued
- Aug 22, 1996
- Abate by
- Aug 27, 1996
Recent events (2)
- · I (O)
- · Z (O)
More inspections in this industry (NAICS 000000)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 300583002.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.