ROCKFORD, IL —
OSHA Inspection: HILLCREST DEVELOPMENT, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HILLCREST DEVELOPMENT, INC. in CLIFFBREAKERS, 700 RIVERSIDE, ROCKFORD, IL 61108 (NAICS 000000). OSHA activity number 300586823.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HILLCREST DEVELOPMENT, INC.
- Site address
- CLIFFBREAKERS, 700 RIVERSIDE
- City
- ROCKFORD
- State
- IL
- ZIP
- 61108
- Mailing
- 404 NORTH GALENA AVE., DIXON, IL 61021
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1542
- Employees
- 3
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Aug 20, 1997
- Abate by
- Sep 8, 1997
- Penalty
- Initial $375 · Current $375
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by falling trusses as a result of the trusses not being braced in accordance with the requirements of the Truss Plate Insitute. Hillcrest Development did not ensure that there was an engineered truss bracing plan for the wood trusses that had a clear span of 84 feet. One feasible abatement method would be to: Follow the recommendations of the Truss Plate Institute HIB-91 and have an engineer design a bracing plan when the truss clear span is over 60 feet. CERTIFICATION REQUIRED FOR THIS ITEM
More inspections at Hillcrest Development, INC.
View Hillcrest Development, INC.'s full OSHA safety record →