CLAY CITY, IL —
OSHA Inspection: M & M PUMP & SUPPLY INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of M & M PUMP & SUPPLY INC. in 307 SE 1ST STREET, CLAY CITY, IL 62824 (NAICS 000000). OSHA activity number 300611316.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & M PUMP & SUPPLY INC.
- Site address
- 307 SE 1ST STREET
- City
- CLAY CITY
- State
- IL
- ZIP
- 62824
- Mailing
- P.O. BOX 525, CLAY CITY, IL 62824
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1389
- Employees
- 65
- Ownership type
- A
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 25, 2000
- Abate by
- Aug 28, 2000
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of being struck-by components of an exploding above-ground oil storage tank. At the Sandblasting Building, on or about 05/31/00, one employee was exposed to the hazards of being struck-by components of an exploding above-ground oil storage tank due to excessive internal pressure being introduced through compressed air. One method of abatement to correct this apparent hazard is to regulate the flow of compressed air into each tank so that an internal pressure of no more than 2.5 PSIG is attained as required by UL-142, paragraph 39.2.1. DISCLAIMER: a) The employer is not limited to the abatement method(s) suggested by OSHA. b) The employer is responsible for selecting and implementing an effective abatement method. ***THIS ITEM REQUIRES A WRITTEN CERTIFICATION OF ABATEMENT***
1910.146 C02
- Issued
- Jul 25, 2000
- Abate by
- Jul 28, 2000
1910.146 C04
- Issued
- Jul 25, 2000
- Abate by
- Aug 28, 2000
1910.305 B02
- Issued
- Jul 25, 2000
- Abate by
- Jul 28, 2000
1910.1200 E01
- Issued
- Jul 25, 2000
- Abate by
- Aug 28, 2000
1904.2 A
- Issued
- Jul 25, 2000
- Abate by
- Jul 28, 2000
1910.37 Q01
- Issued
- Jul 25, 2000
- Abate by
- Jul 28, 2000
1910.38 A01
- Issued
- Jul 25, 2000
- Abate by
- Aug 28, 2000
1910.132 D01
- Issued
- Jul 25, 2000
- Abate by
- Aug 28, 2000
1910.134 C01
- Issued
- Jul 25, 2000
- Abate by
- Aug 28, 2000
1910.178 L01 I
- Issued
- Jul 25, 2000
- Abate by
- Aug 28, 2000
More inspections in this industry (NAICS 000000)