CORTLAND, NY —
OSHA Inspection: PALL TRINITY MICRO DIVISION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PALL TRINITY MICRO DIVISION in 3643 STATE ROUTE 281, CORTLAND, NY 13045 (NAICS 000000). OSHA activity number 300633328.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PALL TRINITY MICRO DIVISION
- Site address
- 3643 STATE ROUTE 281
- City
- CORTLAND
- State
- NY
- ZIP
- 13045
- Mailing
- PO BOX 2030, CORTLAND, NY 13045
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3569
- Employees
- 650
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Aug 23, 1999
- Abate by
- Aug 26, 1999
- Penalty
- Initial $5,000 · Current $3,250 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to THE HAZARD OF BEING CAUGHT-BY INGOING NIP POINTS: a)Dept.#13, Micro Metallic Products, on or about 5/5/99: the company's set-up and operating procedures for the MP-43 roll mill did not include means to ensure protective devices are in safe operating condition and adjustment. Employees exposed to a caught-by hazard. ABATEMENT NOTES: 1.Follow the requirements of American National Standard, ANSI B11.12- 1996, Roll-forming and Roll-bending machines, Section 4.2. 2.Revise set-up and operation procedures for MP-43 roll mill to ensure that protective devices are in safe operating condition and adjustment.
Recent events (2)
- — I (S) $3250.00
- — Z (S) $5000.00
More inspections at Pall Trinity Micro Division
View Pall Trinity Micro Division's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300633328.