VEGA BAJA, PR ·
OSHA Inspection: AUTORIDAD DE ENERGIA ELECTRICA TECNICA
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AUTORIDAD DE ENERGIA ELECTRICA TECNICA in CALLE BETANCES FINAL CARR #2, VEGA BAJA, PR 00694 (NAICS 000000). OSHA activity number 300919503.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUTORIDAD DE ENERGIA ELECTRICA TECNICA
- Site address
- CALLE BETANCES FINAL CARR #2
- City
- VEGA BAJA
- State
- PR
- ZIP
- 00694
- Mailing
- APARTADO 364267 CORREO GENERAL, SAN JUAN, PR 00936
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 4911
- Employees
- 102
- Ownership type
- State government (C)
Citations
1 citation on file for this inspection.
6A0001
- Issued
- Mar 1, 2000
- Abate by
- Mar 6, 2000
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: Explosion and burning hazard; Employees were permitted to work inside of substation and inspected the pressure level of the interrupter OCB-2292 mark G.E. No. K-6569413, code number 070-00-05-03 made on 1948 in which will be replace due the lack of the interrupting capacity and was obsolete system. Employer did not replace the interrupter OCB-2292 when in june 1995 the Division of Study & Planification(AEE) performed study and show that the OCB-2292 did not have enough interrupted capacity for the requirement of the system which must be replace. Location; Substation of AEE(tecnical section) Road #2 Vega Baja P.R. Among other methods, one feasible and acceptable abatement method to correct this hazard is replace the OCB-2292. Riesgo de explosion y quemadura; Empleados fueron permitidos a trabajar dentro de una subestacion y inspeccionar el nivel de presion del interruptor OCB-2292 marca G.E. No. K-6569413, numero codigo 070-00-05-03 fabricado en el 1948 el cual debio ser reemplazado debido a falta de capacidad interruptiva y estar obsoleto el sistema. Patrono no reemplazo interruptor OCB-2292 cuando en junio de 1995 la Division de Planificacion y Estudios de A.E.E. realizo estudio y demostro que el OCB-2292 no tiene la capacidad interruptiva suficiente para los requisitos del sistema el cual debe ser reemplazado. Localizacion; Subestacion de AEE(seccion tecnica) Carretera #2 Vega Baja P.R. Entre otros metodos, un metodo factible y aceptable de correccion para este riesgo es reemplazar el OCB-2292.r
More inspections in this industry (NAICS 000000)
More inspections in PR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 300919503.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.