OSHA Inspection: GIBSON ELECTRIC CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GIBSON ELECTRIC CO., INC. in 11 MIDLANDS DR., SOUTH BARRINGTON, IL 60010 (NAICS 000000). OSHA activity number 300955606.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gibson Electric CO., INC. — free Get an email when a new federal OSHA severe-injury report for Gibson Electric CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
11 MIDLANDS DR.
City
SOUTH BARRINGTON
State
IL
ZIP
60010
Mailing
2100 S. YORK RD., OAKBROOK, IL 60521
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1731
Employees
30
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 02 1 instance 2 exposed
Issued
Feb 3, 1998
Abate by
Feb 6, 1998
Penalty
Initial $1,100 · Current $1,100
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to:
a) Building B, North Entrance, Ticket Booth 145 - Two Gibson Electric Co.,
Inc. employees
were observed climbing above the standard guard rail system of a scissors
lift to gain access to
the roof of the ticket booth to complete conduit work.  The employees were
exposed to a fall
distance of 13 feet 5 inches.  This condition last existed on December 15,
1997.
Among other methods, one feasible and useful method to correct this hazard
is to develop.
implement and enforce a work rule such as stipulated in American National
Standards Institute
A92.6 "American National Standard For Self Propelled Elevating Work
Platforms" 1990.
Personnel shall maintain a firm footing on the platform while working
thereon.  Use of planks,
ladders or any other device on the aerial platform for achieving
additional height or reach shall
prohibited.
Use the provided gate access to scissors lift (self propelled elevating
work platforms) to enter
and exit the lift to access to the top of the ticket booth.
No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1100.00
  • — Z (S) $1100.00

View Gibson Electric CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300955606.