FORDS, NJ —
OSHA Inspection: PMC SPECIALTIES, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of PMC SPECIALTIES, INC. in 20 INDUSTRIAL AVE., FORDS, NJ 08863 (NAICS 000000). OSHA activity number 300985025.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PMC SPECIALTIES, INC.
- Site address
- 20 INDUSTRIAL AVE.
- City
- FORDS
- State
- NJ
- ZIP
- 08863
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2869
- Employees
- 75
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Oct 14, 1999
- Abate by
- Nov 16, 1999
- Penalty
- Initial $3,500 · Current $2,300 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to thermal burns, lung and mucous membrane irritation and/or fire from the release of hot Mono-butyl-para-cresol (MBPC), a combustible organic liquid on May 21, 1999. a- The release occurred when tank #47 overpressurized. Water apparently entered the tank through the venting system, boiling as it contacted hot MBPC and rapidly generating a large volume of vapor. The resulting pressure propelled a blob of MBPC out the emergency vent and swelled the atmospheric tank, causing it to leak. Among other methods, feasible and acceptable abatement methods to correct this hazard include but are not limited to: 1)Design the scrubber system to prevent a backup of water into the vent manifold. This may include means to prevent buildup of organic solids in the scrubber tank overflow trap, high water level alarms and/or frequent checking of the water level site glass. 2)Conduct frequent checks of the system prior to tank usage. Institute a system of reporting problems with the tanks or the venting system. 3)Install reverse flow or check valves wherever possible on the tank ventilation manifold lines. 4)Re-evaluate the tank venting system and emergency venting using the methodology recommended by the AICHE's Design Institute for Emergency Relief System (DIERS Technology) according to the credible worst-case scenario. Condition noted on or about May 24, 1999.
Recent events (2)
- — I (S) $2300.00
- — Z (S) $3500.00
More inspections at PMC Specialties, INC.
View PMC Specialties, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300985025.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.