Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WEDCO

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of WEDCO in 2 VILET FARM ROAD, BLOOMSBURY, NJ 08840 (NAICS 000000). OSHA activity number 300986601.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wedco — free Get an email when a new federal OSHA severe-injury report for Wedco is published. One employer, no account, unsubscribe in one click.
Establishment
WEDCO
Site address
2 VILET FARM ROAD
City
BLOOMSBURY
State
NJ
ZIP
08840
Mailing
P.O. BOX 397, BLOOMSBURY, NJ 08840
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3089
Employees
67
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 15 exposed
Issued
Nov 8, 1999
Abate by
Nov 12, 1999
Penalty
Initial $2,625 · Current $1,600 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  On or
about 09/22/1999,
the employer did not furnish employment and a place of employment which
were free from
recognized hazards that were causing or likely to cause death or serious
physical harm.  A
buildup of static electricity, caused by inadequate bonding and grounding
of filter elements and
a subsequent discharge likely triggered an explosion:
Feasible and acceptable abatement methods to correct this hazard, among
others, are as
follows:
1- Check all dust processing systems and their metal components for proper
grounding
and bonding.  For instance, ensure that the metal cages of the filter
cartridges in the dust
collector housing are adequately bonded and grounded.
2- Instruct employees in the recognition of potential ignition sources in
dust processing
systems.
3- Install connections between the jet mills and dust collectors which can
withstand dust
explosions.
4- Consider retrofitting baghouse systems of dust collectors with
appropriate fire and
explosion suppression systems if they are used for collecting powders with
low minimum
ignition energies and high accumulation potentials such as powders of
polyethylene
waxes.
References:
(a) NFPA 654, Standard for the Prevention of Fire and Dust Explosions in
the Chemical,
Dye, Pharmaceutical and Plastics Industries.
(b) NFPA 69, Standard for Explosion Prevention Systems
(c) NFPA 77, Standard for Static Electricity
(d) Pratt T.H., "Electrostatic Ignitions of Fires and Explosions,"
Burgoyne Incorporated,
Marietta, Georgia 1997, ISBN 0-9659092-0-4.
Recent events (2)
  • — I (S) $1600.00
  • — Z (S) $2625.00

View Wedco's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300986601.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.