Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BETHLEHEM STRUCTURAL PRODUCTS CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BETHLEHEM STRUCTURAL PRODUCTS CORP. in 1805 E. 4TH STREET, BETHLEHEM, PA 18016 (NAICS 000000). OSHA activity number 300987708.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bethlehem Structural Products Corp. — free Get an email when a new federal OSHA severe-injury report for Bethlehem Structural Products Corp. is published. One employer, no account, unsubscribe in one click.
Site address
1805 E. 4TH STREET
City
BETHLEHEM
State
PA
ZIP
18016
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
3312
Employees
1500
Ownership type
A

45 citations on file for this inspection.

5(a)(1)

Unclassified Gravity 02 2 instances 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to a struck-by hazard due to wire rope failure:
a) M.E.R.F., Small Engine Repair Shop - Kinked, and abraded wires were
observed
on the running rope of the three ton electric hoist.  The hoist, mounted
on a jib, was
used to lift the ends of the buggies onto blocks or jack stands for repair.
b) Saw Shop - Permanent distortions (dog leg) were observed in the running
rope of
the 1/2 ton hoist in the shipping/receiving area.  The hoist was used to
transport saw
blades to and from trucks at the dock.
ABATEMENT NOTE:  Among others, one feasible and acceptable method to abate
this
hazard is to replace the wire rope on the hoists.

5(a)(1)

Unclassified Gravity 01 1 instance 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to hazards due to wire rope failure:
a) Auxiliary Shipping Yard; 33 Run - The guide roll on the feed side of
the T-bar
rotary was suspended from a 1/2" wire rope.  The rope was terminated using
a single
wire rope clip on the roll side as well as on the lift cylinder side.  A
single clip does
not properly terminate the 1/2"  wire rope, thus exposing employees to
injury in the
event of clip failure.
b) 2 Battery Door Repair - Wire rope clips used to terminate the hoist
line of the
north crane, west block were applied backward.
c) 10B Conveyor Tube - Two of the five wire rope U-bolt clips used to
terminate the
end of the 1" cable at the A coal tank were applied backward.
ABATEMENT NOTE:  Among others, one feasible and acceptable method to abate
this
hazard is to apply clips as recommended by the manufacturer.

5(a)(1)

Unclassified Gravity 10 1 instance 10 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of a falling load due to improper installation
of the wedge and socket
(becket) fitting(s) on the load line:
a)  420 Saucon Machine Shop - The hoist line on crane #624 was connected
with two (2)
wedge and socket fittings that were installed backwards and the tail of
the rope was
secured with tape thereby exposing the employees to the potential of a
falling load.
Among other methods, one feasible and acceptable method to correct these
hazards is to install
the wedge and socket fitting with the rope in a straight line with the
fitting and secure the tail
with a wire rope clip applied to the tail of the dead end only.

1910.307 B

Unclassified Gravity 03 4 instances 5 exposed
Issued
Dec 17, 1996
Abate by
Mar 15, 1997

1910.184 D

Unclassified Gravity 05 1 instance 10 exposed
Issued
Dec 17, 1996
Abate by
Mar 31, 1997

1910.184 F05 I

Unclassified Gravity 05 3 instances 3 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.184 I09 III

Unclassified Gravity 05 1 instance 3 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.184 F01

Unclassified Gravity 03 1 instance 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.212 A03 II

Unclassified Gravity 03 4 instances 5 exposed
Issued
Dec 17, 1996
Abate by
Mar 31, 1997

1910.217 D05

Unclassified Gravity 03 1 instance 5 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.147 C05 I

Unclassified Gravity 03 1 instance 5 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.147 D04 I

Unclassified Gravity 03 3 instances 3 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.147 D06

Unclassified Gravity 03 1 instance 5 exposed
Issued
Dec 17, 1996
Abate by
Jan 21, 1997

1910.147 C07 I

Unclassified Gravity 03 1 instance 5 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.147 F03 I

Unclassified Gravity 03 1 instance 3 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.151 C

Unclassified Gravity 01 1 instance 1 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.22 C

Unclassified Gravity 03 2 instances 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.23 A05

Unclassified Gravity 03 1 instance 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.23 C01

Unclassified Gravity 03 4 instances 3 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.23 C03

Unclassified Gravity 03 1 instance 1 exposed
Issued
Dec 17, 1996
Abate by
Feb 15, 1997

1910.23 E01

Unclassified Gravity 03 1 instance 1 exposed
Issued
Dec 17, 1996
Abate by
Feb 15, 1997

1910.132 A

Unclassified Gravity 02 1 instance 1 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.219 C02 I

Unclassified Gravity 05 3 instances 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.22 A01

Unclassified Gravity 01 1 instance 1 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.36 D01

Unclassified Gravity 02 1 instance 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.36 B04

Unclassified Gravity 03 1 instance 3 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.179 D03

Unclassified Gravity 10 2 instances 10 exposed
Issued
Dec 17, 1996
Abate by
Mar 31, 1997

1910.179 H02 V

Unclassified Gravity 03 1 instance 10 exposed
Issued
Dec 17, 1996
Abate by
Jan 21, 1997

1926.501 B01

Unclassified Gravity 03 1 instance 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1926.502 D17

Unclassified Gravity 03 1 instance 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1926.503 A01

Unclassified Gravity 03 1 instance 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.106 E02 IIB2

Unclassified Gravity 02 1 instance 1 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.23 D01

Unclassified Gravity 01 2 instances 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.184 C02

Unclassified Gravity 01 1 instance 1 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.147 D04 I

Unclassified Gravity 01 1 instance 5 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.305 B02

Unclassified Gravity 01 2 instances 1 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.180 H02 II

Unclassified Gravity 01 1 instance 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.334 A02 II

Unclassified Gravity 01 1 instance 1 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.303 G02 I

Unclassified Gravity 03 2 instances 1 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.27 D01 V

Unclassified Gravity 01 1 instance 1 exposed
Issued
Dec 17, 1996
Abate by
Feb 15, 1997

1910.179 E04

Unclassified Gravity 01 1 instance 10 exposed
Issued
Dec 17, 1996
Abate by
Jun 30, 1997

1910.179 G02 III

Unclassified Gravity 01 1 instance 10 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.179 G04 I

Unclassified Gravity 01 1 instance 10 exposed
Issued
Dec 17, 1996
Abate by
Mar 31, 1997

1910.179 L02 II

Unclassified Gravity 01 1 instance 2 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996

1910.179 L03 II

Unclassified Gravity 01 6 instances 10 exposed
Issued
Dec 17, 1996
Abate by
Dec 26, 1996
Penalty
Initial $115,000 · Current $115,000

View Bethlehem Structural Products Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300987708.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.