Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: QUALITY REFRACTORY INSTALLATIONS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of QUALITY REFRACTORY INSTALLATIONS in 191 KEIM STREET, POTTSTOWN, PA 19464 (NAICS 000000). OSHA activity number 300989464.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Refractory Installations for free Get an email when a new federal OSHA severe-injury report for Quality Refractory Installations is published. One employer, no account, unsubscribe in one click.
Site address
191 KEIM STREET
City
POTTSTOWN
State
PA
ZIP
19464
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3255
Employees
10
Ownership type
Private (A)

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 2 instances 1 exposed
Issued
Jul 10, 1997
Abate by
Jul 28, 1997
Penalty
Initial $1,750 · Current $875 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to the hazard of being struck by objects due to
failure of wire rope
on the underhung cranes.
a) Shop Area; North Crane, West Hoist -  The READING crane 5 ton hoist was
operated with a running rope having a dog leg distortion and a sheave
showing
corrugations from the wire rope.
b) Shop Area; South Crane, West Hoist - The READING crane 5 ton hoist was
operated with a running rope which was crushed and flattened in at least
two places.
ABATEMENT NOTE: Among others, one feasible and acceptable method to abate
this
hazard is to replace the ropes and sheave on the hoists and to initiate a
program if inspections
on the cranes in accordance with the provisions of American National
Standards Institute
(ANSI) B30.11 Monorail Systems and Underhung Cranes, latest edition.
Abatement certification required within 10 days after abatement date.
The certification
shall include a statement that abatement is complete, date and method of
abatement,
and states employees and their representatives were informed of this
abatement.
Recent events (2)
  • · I (S) $875.00
  • · Z (S) $1750.00

1910.252 B02 IA

Serious Gravity 04 1 instance 1 exposed
Issued
Jul 10, 1997
Abate by
Jul 18, 1997
Penalty
Initial $1,250 · Current $625 Reduced
Recent events (2)
  • · I (S) $625.00
  • · Z (S) $1250.00

1910.179 J02

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Jul 10, 1997
Abate by
Aug 12, 1997

1910.179 J03

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Jul 10, 1997
Abate by
Aug 12, 1997

1910.179 M01

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Jul 10, 1997
Abate by
Aug 12, 1997