HERNANDO, MS —
OSHA Inspection: P & E ELECTRIC CO., INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of P & E ELECTRIC CO., INC. in 1800 MACKINGVALE, HERNANDO, MS 38632 (NAICS 000000). OSHA activity number 301029674.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- P & E ELECTRIC CO., INC.
- Site address
- 1800 MACKINGVALE
- City
- HERNANDO
- State
- MS
- ZIP
- 38632
- Mailing
- P. O. BOX 101013, NASHVILLE, TN 37209
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1623
- Employees
- 15
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 3, 1997
- Abate by
- Jun 13, 1997
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
Section 5(a)(1) of Public Law 91-596, the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to: the hazard of burns. (a)Hernando, MS - During the period from January 1, 1997, through February 20, 1997, the employer allowed employee(s) who were subject to being exposed to energized apparatus, to wear material which was not either flame retardant or 100 cotton of appropriate weight for the conditions they are exposed to. Among other methods one feasible and acceptable method to correct this hazard is require employees exposed wear flame retardant clothing or 100cotton clothing of appropriate weight.
Recent events (2)
- — F (S) $5000.00
- — Z (S) $5000.00
5(a)(1)
- Issued
- Jun 3, 1997
- Abate by
- Jun 27, 1997
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
Section 5(a)(1) of Public Law 91-596, the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to: the hazard of electric shock. (a)Hernando, MS -The following aerial devices were not dielectrically tested on at least an annual basis: i.Truck B8425 - Dielectric tests were not conducted in 1994, 1996 and 1997. ii.Truck B8529 - Dielectric tests were not conducted in 1994, 1996 and 1997. iii.Truck B8552 - Dielectric tests were not conducted in 1995, 1996 and 1997. iv.Truck B8665 - Dielectric tests were not conducted in 1994, 1996 and 1997. v.Truck B8723 - Dielectric tests were not conducted in 1994 and 1995. vi.Truck B8854 - Dielectric tests were not conducted in 1995, 1996 and 1997. Among other methods, one feasible and acceptable abatement method to correct this hazard is to perform dielectric test on all aerial devices on at least an annual basis.
Recent events (2)
- — F (S) $5000.00
- — Z (S) $5000.00
1926.556 B02 V
- Issued
- Jun 3, 1997
- Abate by
- Jun 11, 1997
- Penalty
- Initial $5,000 · Current $5,000
Recent events (2)
- — F (S) $5000.00
- — Z (S) $5000.00
1926.951 A01 III
- Issued
- Jun 3, 1997
- Abate by
- Jun 11, 1997
- Penalty
- Initial $5,000 · Current $5,000
Recent events (2)
- — F (S) $5000.00
- — Z (S) $5000.00
1926.952 A03
- Issued
- Jun 3, 1997
- Abate by
- Jun 11, 1997
- Penalty
- Initial $5,000 · Current $5,000
Recent events (2)
- — F (O) $5000.00
- — Z (S) $5000.00
5(a)(1)
- Issued
- Jun 3, 1997
- Abate by
- Jun 20, 1997
- Penalty
- Initial $55,000 · Current $5,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by and electrical shock hazards: (a)Hernando area jobsite - During the period of January 1, 1997, through February 20, 1997, the employer failed to repair or replace before use the following vehicles which were unsafe: i.Bucket Truck B8529 had a damaged bucket with a cracked liner, needed its bucket covers replaced, had a hydraulic leak in the top control. ii.Bucket Truck B8425 had damaged bucket covers, air leak in top control, leak in top control. iii.Bucket Truck B8854 needed its bucket covers replaced, had a leak on the air tank for the brakes. iv.Bucket Truck B8665 needed it bucket covers replaced. v.Truck D8616 had teeth missing on pinion and bull gears. vi.Truck D8816 had a defective horn and motor blades. Among other methods, one feasible and acceptable abatement method to correct this hazard is to perform dielectric test on all aerial devices on at least an annual basis.
Recent events (2)
- — F (S) $5000.00
- — Z (W) $55000.00
1904.8
- Issued
- Jun 3, 1997
- Abate by
- Jun 6, 1997
- Penalty
- Initial $5,000 · Current $5,000
Recent events (2)
- — F (O) $5000.00
- — Z (O) $5000.00
More inspections at P & E Electric CO., INC.