Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FREE STATE MANUFACTURED HOMES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FREE STATE MANUFACTURED HOMES in 500 EASTVIEW DR., LAUREL, MS 39440 (NAICS 000000). OSHA activity number 301036471.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Free State Manufactured Homes — free Get an email when a new federal OSHA severe-injury report for Free State Manufactured Homes is published. One employer, no account, unsubscribe in one click.
Site address
500 EASTVIEW DR.
City
LAUREL
State
MS
ZIP
39440
Mailing
P. O. BOX 6542, LAUREL, MS 39441
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
2451
Employees
250
Ownership type
A
Industry flags
Manufacturing safety.

25 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 25 exposed
Issued
Sep 15, 1998
Abate by
Mar 1, 1999
Penalty
Initial $7,000 · Current $4,000 Reduced
Section 5(a)(1) of Public Law 91-596, the Occupational Safety and Health
Act of 1970:  The
employer did not furnish employment and a place of employment which were
free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees, in that employees were exposed to hazard of falls at the
worksite known as Free
States Manufactured Homes, 500 Eastview Drive, Laurel, MS, where:
(a)Employees were exposed to the hazard of falling platform/catwalks
supported by
hoists when employees walked and worked approximately 7 feet above floor
level.  The
approximately 90 feet long unguarded platforms/catwalks positioned
alongside the homes
had one brace in the middle and fabricated platforms welded to the
platform ends were
placed unsecured onto a walking working surface.  Additional unguarded
platforms were
placed across the ends of the homes unsecured to the catwalks, all
supported by Coffing
hoists.  (Reference American National Standards Institute (ANSI)
B30.16-1973,
Chapter
16-2, Section 16-2.3.2.3(e) and Coffing Hoists Operating & Maintenance
Instruction
Pub. Part No. EC680-5, Rule 31 "Do not use hoist to lift, support, or
transport people".)
(b)  Employees without fall protection worked on roof areas installing
decking, felt, and
metal roofing materials exposed to falling approximately 13 feet to the
concrete floor.
Among other methods one feasible and acceptable abatement method to
correct this hazard is
to prohibit employees from working on hoisted loads, install underbracing
to support the
intended loads on the work platforms, and use a fall arrest system for
work performed on roof
areas.
Recent events (3)
  • — P (S) $4000.00
  • — I (S) $4000.00
  • — Z (S) $7000.00

5(a)(1)

Serious Gravity 10 1 instance 25 exposed
Issued
Sep 15, 1998
Abate by
Mar 1, 1999
Penalty
Initial $7,000 · Current $4,000 Reduced
Section 5(a)(1) of Public Law 91-596, the Occupational Safety and Health
Act of 1970:  The
employer did not furnish employment and a place of employment which were
free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees, in that employees were exposed to hazard of being struck-by
and/or crushed-by loads
at the worksite known as Free States Manufactured Homes, 500 Eastview
Drive, Laurel, MS,
where:
(a)  Employees were allowed to stand, reach and work underneath hoisted
loads, i.e.,
work platforms/catwalks along the sides and ends. (Reference ANSI
B30.16-1973,
Overhead Hoists, Chapter 16-2, Section 16-2.3.2.3(f) and Coffing Hoist
Operating &
Maintenance Instruction, Pub. Part No. EC680-5, Rule 32 "Do Not lift loads
over
people".)
(b)  Rated load tests to confirm the load rating of the monorail system
with Coffing Hoist
units were not available.  (Reference American National Standards
Institute B30.11-1973,
Monorail Systems and Underhung Cranes, Chapter 11-2, Section 11-2.2.2(a)).
(c)  The lifting devices used with the Coffing hoists did not have the
rated
load marked
on the lifter, nor was a nameplate or other permanent marking displaying
the
manufacturer's name, serial number, lifter weight, and rated load affixed
to the lifters
which are used to move walls, support and move roofs, and support floors
at the
electrical wiring station where support stands were not load rated.
(Reference
ANSI/ASME B30.20-1993, Below-The-Hook Lifting Devices, Chapter 20-1,
Section 20-
1.2.1(a) and (b).
(d)  Roofs supported by lifting devices attached to Coffing hoists were
left unattended
suspended approximatley 12 feet above the floor and no precautions were
taken to
prohibit employees walking underneath the load.  (Reference ANSI
B30.16-1973,
Chapter 16-2, Section 16-2.3.2.3(j)).
Among other methods one feasible and acceptable abatement method to
correct this hazard is
to prohibit employees from working on or reaching under hoisted loads,
install underbracing to
support the intended load on the work platforms, perform load tests and
maintain records of the
monorail system, and affix identifying information to the lifting devices.
Recent events (3)
  • — P (S) $4000.00
  • — I (S) $4000.00
  • — Z (S) $7000.00

1910.23 A07

Serious Gravity 10 2 instances 7 exposed
Issued
Sep 15, 1998
Abate by
Jan 31, 1999
Penalty
Initial $3,500 · Current $2,000 Reduced
Recent events (3)
  • — P (S) $2000.00
  • — I (S) $2000.00
  • — Z (S) $3500.00

1910.23 C01

Serious Gravity 10 1 instance 15 exposed
Issued
Sep 15, 1998
Abate by
Jan 31, 1999
Penalty
Initial $3,500 · Current $2,000 Reduced
Recent events (3)
  • — P (S) $2000.00
  • — I (S) $2000.00
  • — Z (S) $3500.00

1910.147 C04 II

Serious Gravity 02 1 instance 10 exposed
Issued
Sep 15, 1998
Abate by
Mar 31, 1999
Penalty
Initial $1,100 · Current $750 Reduced
Recent events (3)
  • — P (S) $750.00
  • — I (S) $750.00
  • — Z (S) $1100.00

1910.184 C02

Serious Gravity 02 1 instance 15 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998
Penalty
Initial $1,100 · Current $750 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1100.00

1910.212 A05

Serious Gravity 01 1 instance 6 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998
Penalty
Initial $825 · Current $500 Reduced
Recent events (2)
  • — I (S) $500.00
  • — Z (S) $825.00

1910.219 C02 I

Serious Gravity 02 1 instance 5 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998
Penalty
Initial $1,100 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1100.00

1910.219 C04 I

Serious Gravity 02 1 instance 5 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998
Penalty
Initial $1,100 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1100.00

1910.219 E03 I

Serious Gravity 02 2 instances 3 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998
Penalty
Initial $1,100 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1100.00

1910.219 F03

Serious Gravity 02 1 instance 2 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998
Penalty
Initial $1,100 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1100.00

1910.254 D09 III

Serious Gravity 01 1 instance 4 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998
Penalty
Initial $825 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $825.00

1910.304 F05 V

Serious Gravity 02 1 instance 6 exposed
Issued
Sep 15, 1998
Abate by
Sep 18, 1998
Penalty
Initial $1,100 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1100.00

1910.305 B01

Serious Gravity 02 2 instances 3 exposed
Issued
Sep 15, 1998
Abate by
Sep 18, 1998
Penalty
Initial $1,100 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1100.00

1910.305 J02 II

Serious Gravity 01 1 instance 5 exposed
Issued
Sep 15, 1998
Abate by
Sep 18, 1998
Penalty
Initial $825 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $825.00

1910.22 A01

Other-than-serious Gravity 01 1 instance 150 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998

1910.22 D01

Other-than-serious Gravity 01 3 instances 15 exposed
Issued
Sep 15, 1998
Abate by
Mar 1, 1999
Recent events (2)
  • — P (O)
  • — Z (O)

1910.23 D01 III

Other-than-serious Gravity 01 1 instance 20 exposed
Issued
Sep 15, 1998
Abate by
Oct 19, 1998
Recent events (2)
  • — I (O)
  • — Z (O)

1910.26 C02 VII

Other-than-serious Gravity 01 1 instance 10 exposed
Issued
Sep 15, 1998
Abate by
Sep 18, 1998

1910.145 C03

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998

1910.184 D

Other-than-serious Gravity 01 1 instance 15 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998

1910.184 E01

Other-than-serious Gravity 01 1 instance 15 exposed
Issued
Sep 15, 1998
Abate by
Oct 19, 1998
Recent events (2)
  • — I (O)
  • — Z (O)

1910.254 D08

Other-than-serious Gravity 01 1 instance 4 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998

1910.305 G01 IIIA

Other-than-serious Gravity 01 1 instance 15 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998

1910.333 B02 I

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Sep 15, 1998
Abate by
Oct 9, 1998

View Free State Manufactured Homes's full OSHA safety record →