LITTLETON, CO —
OSHA Inspection: THE ELECTRON CORP.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of THE ELECTRON CORP. in 5101 S. RIO GRANDE AVE., LITTLETON, CO 80120 (NAICS 000000). OSHA activity number 301296059.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE ELECTRON CORP.
- Site address
- 5101 S. RIO GRANDE AVE.
- City
- LITTLETON
- State
- CO
- ZIP
- 80120
- Mailing
- PO BOX 318, LITTLETON, CO 80160
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3321
- Employees
- 350
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 17, 1997
- Abate by
- Aug 12, 1997
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing injuries: a) Employees of The Electron Corporation were exposed to crushing injuries while transporting and positioning castings using the Lift-Tech Budgit Series 6000 Man Guard Air Hoist. Sling hooks used to attach the castings to the hoist were not positioned so that the casting weight was supported by the saddle of the hook rather than the hook tips, and employees had not received adequate training in relation to proper placement of loads onto slings and sling hooks, prior to operating the overhead hoists. Among other methods, one feasible and acceptable abatement method is to ensure that manufacturer's recommendations for hoist safety practices are followed, in conjunction with safety standards outlined in ANSI B30.16, and that employees receive formal training in the operation of overhead hoists to meet the definition of a "qualified" operator in ANSI B30.16 prior to operating hoists. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
- — F (S) $6300.00
- — Z (S) $6300.00
1910.178 L
- Issued
- Jul 17, 1997
- Abate by
- Jul 29, 1997
- Penalty
- Initial $1,800 · Current $1,800
Recent events (2)
- — F (S) $1800.00
- — Z (S) $1800.00
1910.184 C09
- Issued
- Jul 17, 1997
- Abate by
- Jul 23, 1997
- Penalty
- Initial $6,300 · Current $6,300
Recent events (2)
- — F (S) $6300.00
- — Z (S) $6300.00
5(a)(1)
- Issued
- Jul 17, 1997
- Abate by
- Oct 9, 1997
- Penalty
- Initial $6,300 · Current $6,300
Recent events (2)
- — F (S) $6300.00
- — Z (S) $6300.00
1910.184 C09
- Issued
- Jul 17, 1997
- Abate by
- Oct 9, 1997
- Penalty
- Initial $6,300
Recent events (2)
- — F (S)
- — Z (S) $6300.00
More inspections at The Electron Corp.
View The Electron Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301296059.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.