WEST DEPTFORD, NJ —
OSHA Inspection: ALLSTATE POWER VAC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of ALLSTATE POWER VAC in MANTUA GROVE RD, WEST DEPTFORD, NJ 08096 (NAICS 000000). OSHA activity number 301318614.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALLSTATE POWER VAC
- Site address
- MANTUA GROVE RD
- City
- WEST DEPTFORD
- State
- NJ
- ZIP
- 08096
- Mailing
- 10 INDUSTRIAL HIGHWAY BLDG "J" MAILSTOP 9, LESTER, PA 19113
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1389
- Employees
- 3
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 28, 1998
- Abate by
- Jul 15, 1998
- Penalty
- Initial $4,900 · Current $2,900 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an explosion/flash fire hazard: a) Mantua Grove Road, Woodbury, NJ 08096 - On or about 11/29/97, employees were vacuuming polypropylene in powder form from a storage silo on the property of Huntsman Polypropylene Corporation utilizing a Vactor Mobile Industrial Vacuum Loading Machine (manufactured by Peabody Meyers) without it being grounded and/or bonded. NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the sections of your publication titled, "Allstate Power-Vac Health and Safety Forms" that address vehicle grounding and bonding. ABATEMENT NOTE: In Accordance with 29 CFR 1903.19, Abatement Verification, the employer will furnish certification that the described hazard has been abated. Documentation may include but is not limited to photographs, videos, work orders, invoices, training records and consultant reports. Abatement documentation must be received by the Area Director within 13 calendar days of the final abatement date for this violation.
Recent events (2)
- — I (S) $2900.00
- — Z (S) $4900.00
More inspections at Allstate Power VAC