COLSTRIP, MT —
OSHA Inspection: MONTANA POWER COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MONTANA POWER COMPANY in COLSTRIP PROJECT DIVISION, COLSTRIP, MT 59323 (NAICS 000000). OSHA activity number 301363701.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MONTANA POWER COMPANY
- Site address
- COLSTRIP PROJECT DIVISION
- City
- COLSTRIP
- State
- MT
- ZIP
- 59323
- Mailing
- PO BOX 38, COLSTRIP, MT 59323
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 4911
- Employees
- 375
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 6, 1998
- Abate by
- Sep 1, 1999
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that; On or about 07/25/98 and at times prior there to, employees working near the Units 3 & 4 Boiler bottom ash hopper systems were exposed to the hazard of being burned by hot water, steam and ash being released through the seal trough. Among other methods, feasible and acceptable abatement methods to correct this hazard are; 1. Follow manufacturers guidelines for maintaining bottom ash removal equipment in order to keep water temperatures at or below 124 degrees. 2. Clear water volume restriction from water lines and sluice pumps to allow ash to be pulled on Units 3 and 4 at the same time when needed. 3. Put acid injection system into service to maintain pH level in the water in order to reduce ash build-up in water lines. 4. Follow manufacturers recommendations and guidelines for maintenance on the boiler components. 5. Increase monitoring and removal of slag and ash accumulation when using a poor fuel quality (dirty coal). 6. Maintain ID Fans so they are able to operate in auto mode rather than manual mode to adjust for pressure fluctuations. 7. Maintain Plum-bobs so they are able to operate in auto mode rather than manual mode in order to assist in adjusting for pressure fluctuations. 8. Increase maintenance and cleaning on scrubber vessels in order to reduce differential pressures in re-heaters and allow ID Fans to adjust to boiler pressures. 9. Consult with the manufacturer of the boiler or a boiler expert about prevention of seal trough blow-outs. (Should not be occurring as per the manufacturer) 10. Perform Job Analysis of JSO's to determine if SOP's are being followed and take steps to ensure that the JSO has adequate time to perform all necessary inspections of boiler on his shift. 11. Consult with the manufacturer of the boiler or a boiler expert about the possibility of a shield on the seal trough to protect employees if the hazard can not be eliminated completely by other means. __ Abatement certification or documentation is NOT required for this item. __ Abatement certification is required for this item. x_ Abatement certification and documentation are required for this item. __ Warning tag (or citation copy) required on this equipment before moving.
Recent events (2)
- — I (S) $5000.00
- — Z (S) $5000.00
1910.23 D01 III
- Issued
- Nov 6, 1998
- Abate by
- Feb 28, 1999
- Penalty
- Initial $3,500 · Current $1,750 Reduced
Recent events (2)
- — I (S) $1750.00
- — Z (S) $3500.00
1910.132 A
- Issued
- Nov 6, 1998
- Abate by
- Nov 9, 1998
- Penalty
- Initial $5,000 · Current $2,500 Reduced
Recent events (2)
- — I (S) $2500.00
- — Z (S) $5000.00
More inspections at Montana Power Company
View Montana Power Company's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301363701.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.