MASON, OH —
OSHA Inspection: WORTHINGTON CUSTOM PLASTICS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of WORTHINGTON CUSTOM PLASTICS, INC. in 4219 NORTH SR 42, MASON, OH 45040 (NAICS 000000). OSHA activity number 301430518.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WORTHINGTON CUSTOM PLASTICS, INC.
- Site address
- 4219 NORTH SR 42
- City
- MASON
- State
- OH
- ZIP
- 45040
- Mailing
- 4219 U.S. ROUTE 42, MASON, OH 45040
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3021
- Employees
- 621
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.23 C01
- Issued
- Jun 25, 1997
- Abate by
- Aug 12, 1997
- Penalty
- Initial $5,950
Recent events (2)
- — F (O)
- — Z (S) $5950.00
5(a)(1)
- Issued
- Jun 25, 1997
- Abate by
- Jul 22, 1997
- Penalty
- Initial $5,950 · Current $5,950
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Employees were exposed to excessive levels of Legionella Pneumophila and Legionella Species in water sprays or mists during injection mold setting and changing operations; parts testing and related activities in the Quality Laboratory; and equipment repair or preventative maintenance. Exposure to these contaminated water sprays and mists could have caused Legionellosis including Legionnaires' disease or Pontiac fever. Water samples collected on March 5 and 13, 1997, analyzed by polymerase chain reaction (PCR) indicated organisms per milliliter (opm) results as follows: DATELOCATIONLEGIONELLA PNEUMOPHILIA Organisms Per Milliliter (opm) LEGIONELLA SPECIES (opm)3/5/97Return side of Press #43 (chilled water west)> 1000 opm estimated (est.) at 1200 > 1000 opm est. at 1500 3/5/97Gage tap of the output of chilled water generator; (chilled water east)est. at 1000 opm>1000 opm est. at 20003/5/97Inlet to the tank of the cooling tower east.< 1000 opm est. at 300 > 1000 opm est. at 12003/5/97In the sump for the water wash paint booths.None detected> 1000 opm est. at 45003/5/97Bag filter for the east press cooling water.< 1000 opm est. at 100> 1000 opm est. at 15003/5/97Return side of Press # 19 (chilled water east)< 1000 opm est. at 10 > 1000 opm est. at 15003/5/97In the west cooling tower tank< 1000 opm est. at 10 > 1000 opm est. at 30003/5/97Chilled water west storage tank< 1000 opm est. at 250 < 1000 opm est. at 8003/13/97Atlas humidity tankNone detected > 1000 opm est. at 12003/13/97Evaporative humidifier in the QC laboratoryNone detectedest. at 1000 opm Abatement of the water systems to control the levels of Legionella bacteria and minimize employees' exposure to water sprays and mists include the following: 1) maintain the cleanliness of the system and the water in it; including effective water filtration systems and periodic cleaning and disinfection of holding tanks and reservoirs; 2) use effective water treatment techniques; including use of biocides, scale removers and corrosion inhibitors, and maintain appropriate pH levels for the treatment selected; 3) avoid water stagnation by assuring circulation through "dead legs" and draining unused water systems; 4) avoid water temperatures and conditions that favor the proliferation of legionella and other micro- organisms; maintain domestic water heaters at 140 degrees fahrenheit and water delivered at the faucet at a minimum of 122 degrees fahrenheit, whenever possible, maintain stored water below 68 degrees fahrenheit and above 122 degrees fahrenheit; 5) inspect circulating water systems and holding tanks at least monthly for leaks and cleanliness; 6) document operation and maintenance of water systems, including water treatments, pH levels and mechanical cleaners; 7) test water systems to assure Legionella levels are not elevated and water maintenance and treatment is effective; 8) minimize aerosolization of water in operations, whenever possible; establish and maintain mold changing and parts testing procedures; 9) train employees on potential sources of exposure to Legionella, routes of exposure, hazards associated with exposure to Legionella, and signs and symptoms of Legionnaires' disease and Pontiac fever.
Recent events (2)
- — F (S) $5950.00
- — Z (S) $5950.00
More inspections at Worthington Custom Plastics, INC.
View Worthington Custom Plastics, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301430518.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.