HAVERTOWN, PA —
OSHA Inspection: DELAWARE VALLEY ERECTORS
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of DELAWARE VALLEY ERECTORS in MANOA SHOPPING CENTER, HAVERTOWN, PA 19083 (NAICS 000000). OSHA activity number 301447116.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DELAWARE VALLEY ERECTORS
- Site address
- MANOA SHOPPING CENTER
- City
- HAVERTOWN
- State
- PA
- ZIP
- 19083
- Mailing
- 654 CROSS KEYS RD., SICKLERVILLE, NJ 08081
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1791
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 4, 1998
- Abate by
- Apr 6, 1998
- Penalty
- Initial $4,200 · Current $2,680 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crush and fall hazards: a) Manoa Shopping Center, Northeast Corner - Employees were exposed to crush and fall hazards. Employees working up on the bar joists were exposed to the likely collapse of the bar joists due to concentrated loads of bundled roof decking being placed on the east end of the bar joists prior to the full and complete installation of all recommended bridging (horizontal bracing) components. Observed 11/12/97. (On 11/12/1997, two employees were up working on the bar joists installing bridging. The employees fell approximately 23 feet when the bars joists on which they were working collapsed. The joists which collapsed, did not have the recommended bridging installed prior to the placement of concentrated loads (bundles of roof decking). ABATEMENT NOTE: Among other methods, one feasible and acceptable means of abatement is to completely install all appropriate bridging prior to the placement of any concentrated loads, such as bundles of roof decking. And also not to exceed the rated load capacity of the bar joists as per the Steel Joist Institute recommendations for erection of open web steel bar joists. NOTE: ABATEMENT DOCUMENTATION REQUIRED.TION
Recent events (2)
- — F (S) $2680.00
- — Z (S) $4200.00
5(a)(1)
- Issued
- Mar 4, 1998
- Abate by
- Mar 9, 1998
- Penalty
- Initial $3,000 · Current $2,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crush and fall hazards: a) Manoa Shopping Center, Interior, West Side - Employee(s) was exposed to crush and fall hazards in that he was operating an elevated scissor lift in an area that contained uncovered/unguarded floor hole(s). On 12/11/1997 an employee who was operating the MX15/19 Upright scissor lift while being elevated approximately 13 feet above the floor, entered an uncovered/unguarded floor hole causing the unit (and the employee in it) to tip over. The employee sustained serious injury. Observed 12/11/97. ABATEMENT NOTE: Among other methods, one feasible and acceptable means of abatement is to have all floor holes appropriately covered or to maintain a safe distance from obstacles, debris, drop-offs, HOLES, depressions, ramps, and other hazards to ensure safe elevated travel as per ANSI A92.6-1990 section 8.10.15.
Recent events (2)
- — F (S) $2000.00
- — Z (S) $3000.00
More inspections at Delaware Valley Erectors
View Delaware Valley Erectors's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301447116.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.