EXTON, PA —
OSHA Inspection: BENSALEM STEEL ERECTORS
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of BENSALEM STEEL ERECTORS in 100 EXTON SQUARE, EXTON, PA 19341 (NAICS 000000). OSHA activity number 301452124.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BENSALEM STEEL ERECTORS
- Site address
- 100 EXTON SQUARE
- City
- EXTON
- State
- PA
- ZIP
- 19341
- Mailing
- 2526 STATE RD., BENSALEM, PA 19020
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1791
- Employees
- 26
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 25, 1999
- Abate by
- Jun 7, 1999
- Penalty
- Initial $1,125 · Current $750 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall and crush hazards: a) Exton Square Mall, Overbuild Area - Employees exposed to the likely collapse of the bar joists due to concentrated loads of bundled steel roof decking being placed on the ends of the joists prior to the complete installation of all recommended bridging (horizontal bracing) components. ABATEMENT NOTE: Among other methods, one feasible means of abatement is to completely install all appropriate bridging prior to the placement of any concentrated loads, such as bundles of roof decking, as per the Steel Joist Institute's recommendation which was located on the field drawings. NOTE: ABATEMENT CERTIFICATION REQUIREDATION
Recent events (2)
- — I (S) $750.00
- — Z (S) $1125.00
More inspections at Bensalem Steel Erectors
View Bensalem Steel Erectors's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301452124.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.