Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE DRESS BARN INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE DRESS BARN INC in 30 DUNNIGAN DRIVE, SUFFERN, NY 10901 (NAICS 000000). OSHA activity number 301461299.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Dress Barn INC — free Get an email when a new federal OSHA severe-injury report for The Dress Barn INC is published. One employer, no account, unsubscribe in one click.
Establishment
THE DRESS BARN INC
Site address
30 DUNNIGAN DRIVE
City
SUFFERN
State
NY
ZIP
10901
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
5632
Employees
275
Ownership type
A
Industry flags
Manufacturing safety.

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 12, 1999
Abate by
Mar 18, 1999
Penalty
Initial $5,000 · Current $3,750 Reduced
Section 5(a)(1): of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were expose to the hazard of being struck and/or crushed by a
moving Pusher
arm:
Location: The Dress Barn, Warehouse
On or About: 02/23/99
a) The employer allowed employees to operate a Padlocker Case Form machine
# 209, with
the interlock switch removed from the sliding door as it was designed to
prevent entry into
the moving machine parts. The removed interlock switch connection was then
placed with its
mate, bypassing the safety interlock system and making it non-functional.
The employees
then operated the Case Form machine while the employees arm was placed
inside the
operating area. The Pusher Arm of the Case Form machine then trapped the
employee's arm
in the machine, between the end of the machine and the Pusher Arm.
AMONG OTHER METHODS ONE FEASIBLE AND ACCEPTABLE
ABATEMENT METHOD TO CORRECT THIS HAZARD IS:
1) All interlocking doors on the Padlocker Case Form machine # 209 shall
be in the closed
position before the machine is operated.
2) The Padlocker Case Form machine # 209 interlocks shall never be removed
from
their
locations at any time.
3) Prior to use of the Padlocker Case machine # 209, and any other similar
equipment,
interlocks switches shall be inspected and tested to ensure they are
functioning properly.
NOTE: The employer is required to submit abatement certification for this
item in
accordance with 29 CFR 1903.19.ce
Recent events (2)
  • — I (S) $3750.00
  • — Z (S) $5000.00

1910.147 C01

Serious Gravity 03 1 instance 2 exposed
Issued
Mar 12, 1999
Abate by
Mar 24, 1999
Penalty
Initial $2,500 · Current $1,875 Reduced
Recent events (2)
  • — I (S) $1875.00
  • — Z (S) $2500.00

1910.147 C04 I

Serious Gravity 03 1 instance 2 exposed
Issued
Mar 12, 1999
Abate by
Mar 24, 1999

1910.147 C05 I

Serious Gravity 03 1 instance 2 exposed
Issued
Mar 12, 1999
Abate by
Mar 24, 1999

1910.147 C07 I

Serious Gravity 03 2 instances 2 exposed
Issued
Mar 12, 1999
Abate by
Mar 24, 1999

View The Dress Barn INC's full OSHA safety record →