UNALASKA OSI DOCK, AK ·
OSHA Inspection: M/V SAVAGE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of M/V SAVAGE, INC. in F/T SEAFISHER, UNALASKA OSI DOCK, AK 99685 (NAICS 000000). OSHA activity number 301497046.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M/V SAVAGE, INC.
- Site address
- F/T SEAFISHER
- City
- UNALASKA OSI DOCK
- State
- AK
- ZIP
- 99685
- Mailing
- 4215 21ST AVENUE WEST, SUITE 207, SEATTLE, WA 98199
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 43
- Ownership type
- Private (A)
- Industry flags
- Maritime safety.
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 13, 2001
- Abate by
- May 31, 2001
- Penalty
- Initial $525 · Current $341 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of electrical shock, burns or electrocution by potential contact with energized, but ungrounded electrical appliances while in a wet or damp location. The following condition contributed to the existence of this hazard: a)F/T Seafisher: The 105 volt electrical outlet located approximately 14 inches from the Galley sink indicated an open ground when tested with IDEAL circuit tester 61-035 and the outlet was not protected by a Ground-Fault-Circuit-Interrupter (GFCI) at the source and/or at the electrical panel. Note: One feasible and useful method of abatement, among others, would be to locate and repair the grounding connection and then replace the old receptacle with a GFCI type receptacle.
Recent events (2)
- · I (S) $341.25
- · Z (S) $525.00
1910.23 C01
- Issued
- Apr 13, 2001
- Abate by
- May 31, 2001
- Penalty
- Initial $875 · Current $875
Recent events (2)
- · I (S) $875.00
- · Z (S) $875.00
1910.151 C
- Issued
- Apr 13, 2001
- Abate by
- May 31, 2001
- Penalty
- Initial $700 · Current $700
Recent events (2)
- · I (S) $700.00
- · Z (S) $700.00
1910.212 A05
- Issued
- Apr 13, 2001
- Abate by
- May 31, 2001
- Penalty
- Initial $700 · Current $455 Reduced
Recent events (2)
- · I (S) $455.00
- · Z (S) $700.00
1918.35
- Issued
- Apr 13, 2001
- Abate by
- Apr 18, 2001
- Penalty
- Initial $875 · Current $875
Recent events (2)
- · I (S) $875.00
- · Z (S) $875.00
1910.23 C01
- Issued
- Apr 13, 2001
- Abate by
- May 31, 2001
- Penalty
- Current $569
Recent events (3)
- · Q $875.00
- · I (S) $568.75
- · Z (S) $875.00
1918.35
- Issued
- Apr 13, 2001
- Abate by
- Apr 18, 2001
Recent events (3)
- · Q $875.00
- · I (S)
- · Z (S) $875.00
1910.253 B02 II
- Issued
- Apr 13, 2001
- Abate by
- Apr 18, 2001
Recent events (2)
- · I (O)
- · Z (O)
1910.253 B04 III
- Issued
- Apr 13, 2001
- Abate by
- Apr 18, 2001
Recent events (2)
- · I (O)
- · Z (O)
More inspections in this industry (NAICS 000000)