NAKNEK, AK —
OSHA Inspection: NORQUEST SEAFOODS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORQUEST SEAFOODS INC in M/V PRIBILOF-NAKNEK, NAKNEK, AK 99366 (NAICS 000000). OSHA activity number 301497269.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORQUEST SEAFOODS INC
- Site address
- M/V PRIBILOF-NAKNEK
- City
- NAKNEK
- State
- AK
- ZIP
- 99366
- Mailing
- 5245 SHILSHOLE AVE NW, SEATTLE, WA 98107
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 86
- Ownership type
- A
- Industry flags
- Maritime safety.
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 5, 2001
- Abate by
- Sep 24, 2001
- Penalty
- Initial $1,275 · Current $765 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a)M/V Pribilof Engine Room: An extension cord was in use to power a portable drill, but the cord was missing its grounding prong thereby exposing the user to the potential hazard of electrical shock and/or burns. NOTE: Among other methods, one feasible and effective abatement method would be to replace the defective plug connector with a new three prong type. b)Refer Flat: A 110/120 volt electrical outlet was missing its cover thereby exposing employees to the potential hazard of electrical shock and/or burns from contact with exposed live parts. NOTE: Among other methods, one feasible and effective abatement method would be to install a new cover. c)Refer Flat: The two 480 volt panels had unused openings in their enclosure which were not effectively closed thereby exposing employees to the potential hazard of electrical shock, burns through inadvertent contact with these panels. NOTE: Among other methods, one feasible and effective abatement method would be to insert a blank snapin cover into each opening. d)Engineers Room: Bare energized light sockets exposed employees to the potential hazard of electrical shock, burns through inadvertent contact with those live parts. NOTE: Among other methods, one feasible and effective abatement method would be to install a light bulb into each socket.
Recent events (2)
- — I (S) $765.00
- — Z (S) $1275.00
1910.215 A04
- Issued
- Sep 5, 2001
- Abate by
- Sep 24, 2001
- Penalty
- Initial $1,275 · Current $765 Reduced
Recent events (2)
- — I (S) $765.00
- — Z (S) $1275.00
1910.215 B09
- Issued
- Sep 5, 2001
- Abate by
- Sep 24, 2001
Recent events (2)
- — I (S)
- — Z (S)
More inspections at Norquest Seafoods INC
View Norquest Seafoods INC's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301497269.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.