TOLEDO, OH —
OSHA Inspection: SUN OIL COMPANY TOLEDO REFINERY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SUN OIL COMPANY TOLEDO REFINERY in WOODVILLE RD AT CITY LIMITS, TOLEDO, OH 43605 (NAICS 000000). OSHA activity number 301531281.
Where did this inspection happen?
- Establishment
- SUN OIL COMPANY TOLEDO REFINERY
- Site address
- WOODVILLE RD AT CITY LIMITS
- City
- TOLEDO
- State
- OH
- ZIP
- 43605
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2911
- Employees
- 500
- Ownership type
- A
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $4500.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to relief valves with set pressures in excess of the maximum allowable working pressure of a pressure valve: In Plant 5, T-501, Serial Number C-2010, constructed for a pressure of 43 psi had had safety relief valves RV-502A and RV-502B. These valves were manufactured by Consolidated, Model No. 1906-RC-1, Serial Numbers TJ31777 and TJ56057. The set pressure for both of these relief valves was 45 psi. Operators working in the area were thereby exposed to the hazards associated with having pressure relef valves set at an operating pressure in excess of the maximum allowable working pressure for a pressure vessel. Feasible methods of abatement include, but are not limited to, the following: 1)Select and install pressure relief valves that meet the requirements of Section VIII of the American Society of Mechanical Engineers ((ASME) Pressure Vessel Code. 2) Re-rate the maximum allowable working pressure of the pressure vessel in excess of the set pressures of the pressure relief valves as set forth in Section VIII of the ASME Pressure Vessel Code.
Recent events (2)
- — I (S)
- — Z (S) $4500.00
1910.23 C03
- Issued
- Abate by
- Penalty
- Initial $2250.00 · Current $2250.00
Recent events (2)
- — A (S) $2250.00
- — Z (S) $2250.00
1910.27 C04
- Issued
- Abate by
- Penalty
- Initial $2250.00 · Current $2250.00
Recent events (2)
- — A (S) $2250.00
- — Z (S) $2250.00
1910.119 D03 IB
- Issued
- Abate by
- Penalty
- Initial $4500.00
Recent events (2)
- — I (S)
- — Z (S) $4500.00
1910.119 E05
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $1000.00 Reduced
Recent events (2)
- — A (S) $1000.00
- — Z (S) $4500.00
1910.119 F04
- Issued
- Abate by
- Penalty
- Initial $2250.00
Recent events (2)
- — I (S)
- — Z (S) $2250.00
1910.134 B11
- Issued
- Abate by
- Penalty
- Initial $2250.00
Recent events (2)
- — I (S)
- — Z (S) $2250.00
1910.134 D02 I
- Issued
- Abate by
- Penalty
- Initial $2250.00 · Current $2250.00
Recent events (2)
- — A (S) $2250.00
- — Z (S) $2250.00
1910.147 C05 II
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $4500.00
Recent events (2)
- — A (S) $4500.00
- — Z (S) $4500.00
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $4500.00
Recent events (2)
- — I (S)
- — Z (S) $4500.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $4500.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to relief valves with set pressures in excess of the maximum allowable working pressure of a pressure valve: In Plant 5, T-501, Serial Number C-2010, constructed for a pressure of 43 psi had had safety relief valves RV-502A and RV-502B. These valves were manufactured by Consolidated, Model No. 1906-RC-1, Serial Numbers TJ31777 and TJ56057. The set pressure for both of these relief valves was 45 psi. Operators working in the area were thereby exposed to the hazards associated with having pressure relef valves set at an operating pressure in excess of the maximum allowable working pressure for a pressure vessel. Feasible methods of abatement include, but are not limited to, the following: 1)Select and install pressure relief valves that meet the requirements of Section VIII of the American Society of Mechanical Engineers ((ASME) Pressure Vessel Code. 2) Re-rate the maximum allowable working pressure of the pressure vessel in excess of the set pressures of the pressure relief valves as set forth in Section VIII of the ASME Pressure Vessel Code.
Recent events (2)
- — I (O)
- — Z (S) $4500.00
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $4500.00
Recent events (2)
- — A (O)
- — Z (S) $4500.00
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in OH
DAYTON, OH—2026-07-17 00:00:00
TEKNOL, INC.
PAYNE, OH—2026-07-16 00:00:00
LIPPERT
SUGARCREEK, OH—2026-07-16 00:00:00
PROVIA
CINCINNATI, OH—2026-07-16 00:00:00
GREENACRES FOUNDATION
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
Source