Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: MAALDI COLD STORAGE, INC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of MAALDI COLD STORAGE, INC in 300 N. CONCEPCION, EL PASO, TX 79901 (NAICS 000000). OSHA activity number 301571394.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Maaldi Cold Storage, INC for free Get an email when a new federal OSHA severe-injury report for Maaldi Cold Storage, INC is published. One employer, no account, unsubscribe in one click.
Site address
300 N. CONCEPCION
City
EL PASO
State
TX
ZIP
79901
Mailing
1041 SINGING HILLS, EL PASO, TX 79912
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
4226
Employees
18
Ownership type
Private (A)

10 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 9 exposed
Issued
Jan 3, 2002
Abate by
Feb 6, 2002
Penalty
Initial $1,500 · Current $300 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to:
a)The employer used and charged an anhydrous ammonia refrigeration system
with
farm-grade anhydrous ammonia, which contained as much as 2water, instead
of
refrigeration-grade ammonia, which ANSI/IIAR 2-1999 (Equipment, Design, and
Installation of Ammonia Mechanical Refrigerating Systems) states shall
have a
maximum of 33 ppm water content.  The water content can form ice in the
lines
and block ammonia flow in the system, which can lead to a rupture in an
ammonia
containing line.  An abatement method would have been to remove water from
the
lines and to charge the system with refrigeration-grade
ammoniaration-grade
Recent events (2)
  • · I (S) $300.00
  • · Z (S) $1500.00

1910.134 C01 IX

Serious Gravity 01 1 instance 3 exposed
Issued
Jan 3, 2002
Abate by
Jan 30, 2002
Penalty
Initial $450 · Current $90 Reduced
Recent events (2)
  • · I (S) $90.00
  • · Z (S) $450.00

1910.134 E01

Serious Gravity 01 1 instance 3 exposed
Issued
Jan 3, 2002
Abate by
Feb 6, 2002
Penalty
Initial $450 · Current $90 Reduced
Recent events (2)
  • · I (S) $90.00
  • · Z (S) $450.00

1910.134 H03 IB

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 3, 2002
Abate by
Jan 23, 2002
Penalty
Initial $1,500 · Current $300 Reduced
Recent events (2)
  • · I (S) $300.00
  • · Z (S) $1500.00

1910.178 L

Serious Gravity 03 1 instance 5 exposed
Issued
Jan 3, 2002
Abate by
Jan 23, 2002
Penalty
Initial $750 · Current $150 Reduced
Recent events (2)
  • · I (S) $150.00
  • · Z (S) $750.00

1910.178 M12

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 3, 2002
Abate by
Jan 9, 2002
Penalty
Initial $1,500 · Current $300 Reduced
Recent events (2)
  • · I (S) $300.00
  • · Z (S) $1500.00

1910.307 B

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 3, 2002
Abate by
Jan 15, 2002
Penalty
Initial $1,500 · Current $300 Reduced
Recent events (2)
  • · I (S) $300.00
  • · Z (S) $1500.00

1910.1200 G01

Serious Gravity 03 1 instance 10 exposed
Issued
Jan 3, 2002
Abate by
Feb 6, 2002
Penalty
Initial $750 · Current $150 Reduced
Recent events (2)
  • · I (S) $150.00
  • · Z (S) $750.00

1910.1200 H01 I

Serious Gravity 03 1 instance 9 exposed
Issued
Jan 3, 2002
Abate by
Feb 6, 2002
Penalty
Initial $750 · Current $150 Reduced
Recent events (2)
  • · I (S) $150.00
  • · Z (S) $750.00

1910.1200 H01 II

Serious Gravity 03 1 instance 9 exposed
Issued
Jan 3, 2002
Abate by
Feb 6, 2002
Recent events (2)
  • · I (S)
  • · Z (S)

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 301571394.