Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: S & A PROPERTIES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of S & A PROPERTIES in 3725 SEVERN RD., CLEVELAND HTS, OH 44118 (NAICS 000000). OSHA activity number 301917423.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S & a Properties — free Get an email when a new federal OSHA severe-injury report for S & a Properties is published. One employer, no account, unsubscribe in one click.
Establishment
S & A PROPERTIES
Site address
3725 SEVERN RD.
City
CLEVELAND HTS
State
OH
ZIP
44118
Mailing
3405 DESOTA, CLEVELAND HEIGHTS, OH 44118
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1761
Employees
7
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 7 exposed
Issued
Jul 29, 1998
Abate by
Aug 3, 1998
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employmnent and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to:
On or about July 9, 1998, at 3725 Severn Rd, Cleveland Heights, OH,
employees were exposed
to the hazards of a roof collapse resulting in serious injuries such as
broken bones, skull
fractures and lacerations while leveling and securing wood trusses
approximately 40 feet long.
The shift of approximately 50 sheets of 4 ft x 8 ft plywood roof sheating,
separated into two
piles placed along side each other on the west end of the structure,
caused the trusses to collapse
under their weight.
This hazard can be abated by ensuring all trusses are level and secure
prior to the placement of
any roofing material on top of them.
NOTE:  Per TPI, Truss Plate Institute, with regards to installing,
securing and loading of trusses
approximately 40 feet long; the installer must assure all permanent
bracing is installed prior to
the placing of any loads on them.