CLEVELAND HTS, OH —
OSHA Inspection: S & A PROPERTIES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of S & A PROPERTIES in 3725 SEVERN RD., CLEVELAND HTS, OH 44118 (NAICS 000000). OSHA activity number 301917423.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S & A PROPERTIES
- Site address
- 3725 SEVERN RD.
- City
- CLEVELAND HTS
- State
- OH
- ZIP
- 44118
- Mailing
- 3405 DESOTA, CLEVELAND HEIGHTS, OH 44118
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1761
- Employees
- 7
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 29, 1998
- Abate by
- Aug 3, 1998
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: On or about July 9, 1998, at 3725 Severn Rd, Cleveland Heights, OH, employees were exposed to the hazards of a roof collapse resulting in serious injuries such as broken bones, skull fractures and lacerations while leveling and securing wood trusses approximately 40 feet long. The shift of approximately 50 sheets of 4 ft x 8 ft plywood roof sheating, separated into two piles placed along side each other on the west end of the structure, caused the trusses to collapse under their weight. This hazard can be abated by ensuring all trusses are level and secure prior to the placement of any roofing material on top of them. NOTE: Per TPI, Truss Plate Institute, with regards to installing, securing and loading of trusses approximately 40 feet long; the installer must assure all permanent bracing is installed prior to the placing of any loads on them.