CLEVELAND, OH —
OSHA Inspection: EUCLID CHEMICAL CO.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of EUCLID CHEMICAL CO. in 19218 REDWOOD RD., CLEVELAND, OH 44110 (NAICS 000000). OSHA activity number 301918280.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EUCLID CHEMICAL CO.
- Site address
- 19218 REDWOOD RD.
- City
- CLEVELAND
- State
- OH
- ZIP
- 44110
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2821
- Employees
- 100
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 16, 1998
- Abate by
- Nov 18, 1998
- Penalty
- Initial $3,500 · Current $2,450 Reduced
03720921T196
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential chemical burns and explosion hazards: On August 11, 1998, Vat B of the Epoxy Packaging (Liquid Fill) machine overfilled, causing the lid to fly off and liquid epoxy to release onto the operator and elsewhere. The epoxy contains ingredients that cause eye damage, skin burns and allergic sensitization. Vats A and B are reservoir containers made of 18 gauge stainless steel, 18 inches in diameter, holding approximately 11 gallons; in this application they are used exclusively for epoxy products (Flash Points over 200 degrees F.), not for flammable liquids. Vats A and B are pressure vessels in that they are designed for operation at pressures greater than 15 psi; specifically the vessel can sustain continuous pressure of 50 psi, the pressure relief valve does not actuate until at least 25 psi, and the manufacturer's instruction manual states that they "can be pressurized up to 18 psi". The vessel was not in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII, 1995 (with 1997 Addenda). a) The lids of the vats were not constructed in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, UG-35(b), "Quick-Actuating Closure (Quick-Opening Closures)", which states as follows: Closures other than the multibolted type designed to provide access to the contents space of a pressure vessel shall have a locking mechanism or locking device so designed that failure of any one locking element or component in the locking mechanism cannot result in the failure of all other locking elements and the release of the closure. b) The pressure relief devices were not in accordance with ASME Boiler and Vessel Code, Section VIII, UG-125(c), "Pressure Relief Devices - General", which states as follows: All pressure vessels other than unfired steam vessels shall be protected by a pressure relief device that shall prevent the pressure from rising more than 10 or 3 psi, whichever is greater, above the maximum allowable working pressure. c) The seal band was not tightened in accordance with the manufacturer's instructions which state as follows : Tighten nuts on pressure tank seal band until coil springs touch each other. d) The float system was not inspected in accordance with the manufacturer's instructions which state as follows: Holding the tank lid level, or float system cover, manually lift each of the floats and observe the inlet valves open and close appropriately when the upper ball is lifted.e) The pressure relief valve was not inspected in accordance with the manufacturer's instructions which state as follows: Open the pressure relief valve at least weekly to make sure it is not blocked, closed or obstructed or otherwise disabled. f) The reservoir vats were not marked in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, UG-116(a) and (b), "Required Marking". g) The pressure relief valves were not marked in accordance with ASME Boiler and Pressure Vessel Code., Section VIII, UG-129(a), "Marking - Safety, Safety Relief, Relief, Liquid Pressure Relief, and Pilot Operated Pressure Relief Valves". Note: Feasible and acceptable abatement methods include but are not limited to: 1) Retrain all operators and supervisors on the correct method of assuring adequate tightness of the seal band; 2) Place labels on both sides of the vats with instructions on proper tightening; 3) Add audible fill level and pressure level alarms to Vats A and B; 4) Retrain the employees on inspection, cleaning, the significance of the displays on the control panel, and procedures to follow if the alarms are activated; 5) Require the operators to complete a thorough inspection of the equipment at the start of each shift or before its use, including but not limited to the cleanliness and proper functioning of the floats and pressure gauges, preferably utilizing a written checklist to provide a record of the inspection; 6) Require the supervisors to check the equipment on a random basis, including but not limited to cleanliness, the tightness of the seal band, and proper functioning of the float and pressure relief valve; 7) Enforce the inspection and cleaning requirements, through disciplinary measures if necessary; 8) Train operators and supervisors to conduct complete incident investigation for accident and "near miss" incidents, including recommendations for prevention; 9) Implement recommended improvements wherever practical.
Recent events (2)
- — I (S) $2450.00
- — Z (S) $3500.00
1910.106 E02 IIB2
- Issued
- Oct 16, 1998
- Abate by
- Oct 21, 1998
- Penalty
- Initial $1,100 · Current $770 Reduced
25902270
Recent events (2)
- — I (S) $770.00
- — Z (S) $1100.00
1910.106 E06 II
- Issued
- Oct 16, 1998
- Abate by
- Oct 24, 1998
- Penalty
- Initial $1,100 · Current $770 Reduced
25902270
Recent events (2)
- — I (S) $770.00
- — Z (S) $1100.00
1910.110 F02 I
- Issued
- Oct 16, 1998
- Abate by
- Oct 22, 1998
- Penalty
- Initial $1,375 · Current $962 Reduced
2150
Recent events (2)
- — I (S) $962.00
- — Z (S) $1375.00
1910.132 A
- Issued
- Oct 16, 1998
- Abate by
- Oct 24, 1998
03720921T196
Recent events (2)
- — I (S)
- — Z (S)
1910.151 C
- Issued
- Oct 16, 1998
- Abate by
- Dec 31, 1998
- Penalty
- Initial $1,375
0921T196
Recent events (3)
- — P (S)
- — I (S)
- — Z (S) $1375.00
More inspections at Euclid Chemical CO.
View Euclid Chemical CO.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301918280.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.