HACKENSACK, NJ —
OSHA Inspection: HEIGHTS ELEVATOR INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HEIGHTS ELEVATOR INC. in 170 PROSPECT ST., HACKENSACK, NJ 07601 (NAICS 000000). OSHA activity number 301952321.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEIGHTS ELEVATOR INC.
- Site address
- 170 PROSPECT ST.
- City
- HACKENSACK
- State
- NJ
- ZIP
- 07601
- Mailing
- 1755 FRONT ST., YORKTOWN HEIGHTS, NY 10598
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1799
- Employees
- 4
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
3 citations on file for this inspection.
1926.552 A01
- Issued
- Oct 26, 1998
- Abate by
- Oct 29, 1998
- Penalty
- Initial $1,000
Recent events (2)
- — I (S)
- — Z (S) $1000.00
1926.552 A02
- Issued
- Oct 26, 1998
- Abate by
- Oct 29, 1998
- Penalty
- Initial $800 · Current $800
5(a)(1)
- Issued
- Oct 26, 1998
- Abate by
- Oct 29, 1998
- Penalty
- Initial $27,500 · Current $5,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of falls, of being struck by the moving elevator car, and of having parts of their body caught in the sheer point created by the elevator moving between floors, resulting from inappropriate installation of an elevator: a)Elevator #3, Floor 18: The full width of the landing opening was not protected to its full height with doors, on or about 8/19/98. b)Elevator #3: Elevator car gate was not provided with a car gate electric contact, on or about 8/19/98. Abatement note: One feasible and acceptable method of abatement to correct the hazards is to comply with ASME A17.1, Safety Code for Elevators and Escalators, Part 19, Elevators Used for Construction, Rule 1900.6 Hoistway Doors and Gates, and Rule 1902.7 Car Doors or Gates.
Recent events (2)
- — I (W) $5000.00
- — Z (W) $27500.00
More inspections at Heights Elevator INC.
View Heights Elevator INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301952321.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.