Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALLSTATE MECANICAL SUBCONTRACTORS, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ALLSTATE MECANICAL SUBCONTRACTORS, INC. in 2000 AVONDALE, DURHAM, NC 27704 (NAICS 000000). OSHA activity number 301963146.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Allstate Mecanical Subcontractors, INC. — free Get an email when a new federal OSHA severe-injury report for Allstate Mecanical Subcontractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2000 AVONDALE
City
DURHAM
State
NC
ZIP
27704
Mailing
161 VISTA LANE, PELLCITY, AL 35125
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1711
Employees
4
Ownership type
A
Industry flags
Construction safety.

3 citations on file for this inspection.

95012901

Serious Gravity 02 1 instance 2 exposed
Issued
Feb 4, 1998
Abate by
Feb 9, 1998
Penalty
Initial $350 · Current $350
North Carolina General Statue 95-129(1) of the Occupational
Safety and Health Act of North Carolina:  The employer did not
furnish to each of his employees condition of employment and a
place of employment which were free from recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees were exposed to a fall to a lower
elevation:
a)Southeast Corner of Winn-Dixie site - two employees
using a Strato-Lift and Boom aerial lift were working
while standing on the top rails 10' 2" above the floor
and did not have a firm footing on the platform floor
and was not wearing any fall arrest equipment (ref.
ANSI/SIA A92.6-1990, 7-11.1).
One feasible and acceptable abatement method, among others, to
correct this hazard is to always park the scissors lift in a
position relative to the work to be performed so that the
employee can stand within the confines of the platform to perform
the work.rm

1926.20 B03

Serious Gravity 02 1 instance 2 exposed
Issued
Feb 4, 1998
Abate by
Feb 22, 1998

1926.454 A

Serious Gravity 02 1 instance 2 exposed
Issued
Feb 4, 1998
Abate by
Feb 9, 1998

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301963146.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.