Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WIGINTON FIRE SPRINKLERS, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of WIGINTON FIRE SPRINKLERS, INC. in 9155 ELLIS ROAD, MELBOURNE, FL 32904 (NAICS 000000). OSHA activity number 302026356.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wiginton Fire Sprinklers, INC. — free Get an email when a new federal OSHA severe-injury report for Wiginton Fire Sprinklers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9155 ELLIS ROAD
City
MELBOURNE
State
FL
ZIP
32904
Mailing
4356 FORTUNE PLACE, SUITE D, W. MELBOURNE, FL 32904
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1711
Employees
2
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 1 exposed
Issued
Nov 4, 1998
Abate by
Dec 7, 1998
Penalty
Initial $1,300 · Current $900 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees were
exposed to the hazard of being pulled into and crushed by the rotating
parts of a pipe
threading machine:
(a) 9155 Ellis Road, Melbourne, FL, employees operated a Rigid 300 pipe
threading machine
which was activated by a toggle switch that would not automatically shut
the machine off if
the operator was inadvertently caught up in its rotating parts, on or
about September 30,
1998.
ABATEMENT NOTES:
Among other methods, one feasible and acceptable method to eliminated this
hazard is to
follow the American National Institute Safety Standard for Portable Pipe
Threading
Machines
and Portable Power Drives - Safety Requirements (ANSI B208.1-1982),
Section 4.4, which
states as follows: "a momentary contact device shall be used to control
the power input to the
cord-connected portable pipe threading machine or power drive.  If a foot
switch is used, it
shall be guarded:.
Recent events (2)
  • — I (S) $900.00
  • — Z (S) $1300.00

View Wiginton Fire Sprinklers, INC.'s full OSHA safety record →