CORPUS CHRISTI, TX —
OSHA Inspection: FULTON CONSTRUCTION/COASTCON CORPORATION, A JOINT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FULTON CONSTRUCTION/COASTCON CORPORATION, A JOINT in 1200 NORTH WATER STREET, CORPUS CHRISTI, TX 78401 (NAICS 000000). OSHA activity number 302103742.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FULTON CONSTRUCTION/COASTCON CORPORATION, A JOINT
- Site address
- 1200 NORTH WATER STREET
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78401
- Mailing
- P O BOX 9486, CORPUS CHRISTI, TX 78469
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1542
- Employees
- 25
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- May 11, 2000
- Abate by
- May 15, 2000
- Penalty
- Initial $2,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a fall hazard: Employees were exposed to a fall hazard of approximately fifty-eight (58) feet to sixty-eight (68) feet to ground level due to improper usage and placement of the Crosby clips. a.The employer had used two (2) Crosby clips on a each end of a one-half (1/2) inch wire rope lifeline where it passed through a drilled hole in the steel flat bar at the top of an upright steel pipe support stanchion. The dead end was secured alongside of the live end of the one-half (1/2) inch wire rope. b.The employer had improperly placed the Crosby clips on each end of a one-half (1/2) inch wire lifeline where it passed through a drilled hole in the steel flat bar at the top of an upright steel pipe support stanchion. The dead end was secured alongside of the live end of the one-half (1/2) inch wire rope, i.e. The saddle of the Crosby clip had been installed on the dead end of the wire rope and the "U" bolt side of the Crosby clip had been installed on the live end of the wire rope thus crimping the wires of the wire rope and impairing their integrity. c.The employer did not provide a properly formed eye termination at both ends of the one-half (1/2) inch wire rope horizontal lifeline; at the two (2) ends where the turnbuckle was connected. A properly formed eye termination can be formed by incorporating a properly sized thimble. This is where the one-half (1/2) inch wire rope horizontal lifeline passes through a drilled hole in the steel flat bar at the top of an upright steel pipe support stanchion on both ends and in the center where the one-half (1/2) inch wire rope passes through the eye bolt on each end of the turnbuckle. This occurred on or about January 26, 2000 at the new U.S. Federal Courthouse construction jobsite at 1200 North Water Street, Corpus Christi, Texas 78401. Among other methods, one feasible and acceptable abatement method to correct this hazard would be installation of a properly installed one-half (1/2) inch wire rope lifeline using three (3) Crosby clips properly placed and with the saddles of the Crosby clip placed on the live side of the one-half (1/2) inch wire rope horizontal lifeline, along with the use of a properly formed eye termination which is formed by incorporating a properly sized thimble, as required by the manufacturers recommended specifications and as specified in ANSI Z359.1 1992.
Recent events (2)
- — F (S)
- — Z (S) $2500.00
1926.502 D08
- Issued
- May 11, 2000
- Abate by
- May 15, 2000
- Penalty
- Initial $2,500
Recent events (2)
- — F (S)
- — Z (S) $2500.00
1926.502 D11
- Issued
- May 11, 2000
- Abate by
- May 15, 2000
- Penalty
- Initial $2,500 · Current $2,500
Recent events (2)
- — F (O) $2500.00
- — Z (S) $2500.00
1926.150 C01 VIII
- Issued
- May 11, 2000
- Abate by
- May 15, 2000