OSHA Inspection: CORPUS CHRISTI DRILLING & WORKOVER L.L.C. RIG #5

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CORPUS CHRISTI DRILLING & WORKOVER L.L.C. RIG #5 in 2 MI. E. HWY 359 ON FM 1539 1/4 MI. N., ALFRED, TX 78372 (NAICS 000000). OSHA activity number 302105820.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Corpus Christi Drilling & Workover L.L.C. RIG #5 — free Get an email when a new federal OSHA severe-injury report for Corpus Christi Drilling & Workover L.L.C. RIG #5 is published. One employer, no account, unsubscribe in one click.
Site address
2 MI. E. HWY 359 ON FM 1539 1/4 MI. N.
City
ALFRED
State
TX
ZIP
78372
Mailing
311 SARATOGA, CORPUS CHRISTI, TX 78417
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1381
Employees
12
Ownership type
A
Industry flags
Manufacturing safety.

17 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 30, 2000
Abate by
Sep 3, 2000
Penalty
Initial $2,500 · Current $2,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to a fire or explosion hazard:
Employee was exposed to the hazard of fire and explosion due to the
improper
rigging of the Geronimo Emergency Escape and installation of the Geronimo
Emergency Escape Device on the Geronimo Emergency Escape Line due to:
a.The Geronimo Emergency Escape Device and Line were installed next to
the monkey board 65 feet above the ground with the line running down
the west derrick leg with no safe egress.
b.The Emergency Escape Line was not anchored/staked out as
recommended by the manufacturer Geronimo Manufacturing, Inc.
This occurred on July 10,2000 on Corpus Christi Drilling & Workover L.L.C.
Rig #5. Among other methods for abatement, one feasible and acceptable
abatement method to correct this hazard would be installation of a
properly
rigged
and secured emergency descent device or other satisfactory auxiliary means
of
egress, such as specified in Section 5, Sub-Section 5.7, Paragraph 5.7.1 of
American Petroleum Institute (API) RP 54-92, Page 12. Essential elements
of this
procedure would include:
1.Staking out securely anchored one-half inch wire rope line to the derrick
or mast so as to provide a ready and convenient means of escape from the
derrick mans's working platform.
2.The escape line route is to be kept clear of obstructions.
3.A safety device is to be provided to permit fast emergency exit from the
derrick man's working platform to a safe place.
4.The tension on the escape line is to be periodically checked and adjusted
to assure a safe landing and to allow the derrick man to stop 20 to 25 feet
from the anchor point.
5.The ground anchor point of the escape line is to be located a minimum
lateral distance from the derrick or mast equal to the height above ground
level to the point where the escape line is fastened.

5(a)(1)

Serious Gravity 10 6 instances 12 exposed
Issued
Aug 30, 2000
Abate by
Sep 3, 2000
Penalty
Initial $2,500 · Current $2,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to a collapsed mast (derrick) hazard:
The hazard of collapsed mast (derrick) of a drilling rig resulting from
failure to
install wire rope guylines with correctly installed Crosby clips on all
four side of
the rig as recommended by the manufacturer's specifications for the safe
guying
of the mast to ensure adequate anchorage in the following:
a.Four guylines incorrectly installed Crosby clips.
b.Geronimo emergency Escape Line incorrectly installed Crosby clips.
c.Catline on the rig floor incorrectly installed Crosby clips.
This occurred on July 12, 2000 on Corpus Christi Drilling & Workover L.L.C.
Rig #5. Among other methods of abatement, one feasible and acceptable
abatement method to correct this hazard would be installation of a properly
secured guylines as specified in the American Petroleum Institute Second
edition,
paragraph 3.14 of Spec 4e and American Petroleum Institute Standard 4d
sixth
edition paragraph 3.4 and American Petroleum Standard 4f, appendix c16,
first
edition May 01,1985.Essential elements of this procedures would include:
1.Hand screwed in auger anchors into the soil according to the
Manufacturer's recommended specifications.
2.Wire rope guylines properly secured to the raised portion of the auger
anchor.
3.Also correctly install and properly secure the Crosby clips to the ends
of
the wire rope guylines.

1910.23 A01

Serious Gravity 01 1 instance 7 exposed
Issued
Aug 30, 2000
Abate by
Sep 3, 2000
Penalty
Initial $525 · Current $525

1910.23 C01

Serious Gravity 01 2 instances 5 exposed
Issued
Aug 30, 2000
Abate by
Sep 3, 2000
Penalty
Initial $525 · Current $525

1910.133 A01

Serious Gravity 05 2 instances 2 exposed
Issued
Aug 30, 2000
Abate by
Sep 4, 2000
Penalty
Initial $1,225 · Current $1,225

1910.138 A

Serious Gravity 05 2 instances 2 exposed
Issued
Aug 30, 2000
Abate by
Sep 4, 2000
Penalty
Initial $1,225 · Current $1,225

1910.151 C

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 30, 2000
Abate by
Sep 4, 2000
Penalty
Initial $2,500 · Current $2,500

1910.157 C04

Serious Gravity 01 2 instances 15 exposed
Issued
Aug 30, 2000
Abate by
Sep 4, 2000
Penalty
Initial $525 · Current $525

1910.219 D01

Serious Gravity 02 1 instance 5 exposed
Issued
Aug 30, 2000
Abate by
Sep 4, 2000
Penalty
Initial $700 · Current $700

1910.219 E01 I

Serious Gravity 02 1 instance 5 exposed
Issued
Aug 30, 2000
Abate by
Sep 4, 2000

1910.304 F04

Serious Gravity 02 1 instance 5 exposed
Issued
Aug 30, 2000
Abate by
Sep 5, 2000
Penalty
Initial $700 · Current $700

1910.1200 E01

Serious Gravity 01 1 instance 2 exposed
Issued
Aug 30, 2000
Abate by
Sep 7, 2000
Penalty
Initial $525 · Current $525

1910.1200 G01

Serious Gravity 01 1 instance 7 exposed
Issued
Aug 30, 2000
Abate by
Sep 7, 2000

1910.1200 H01

Serious Gravity 01 1 instance 7 exposed
Issued
Aug 30, 2000
Abate by
Sep 12, 2000

1904.2 A

Other-than-serious Gravity 00 2 instances 100 exposed
Issued
Aug 30, 2000
Abate by
Sep 7, 2000

1910.151 B

Other-than-serious Gravity 01 1 instance 7 exposed
Issued
Aug 30, 2000
Abate by
Sep 7, 2000

1910.184 E01

Other-than-serious Gravity 01 1 instance 7 exposed
Issued
Aug 30, 2000
Abate by
Sep 7, 2000