OSHA Inspection: ELGIN DAIRY FOODS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ELGIN DAIRY FOODS, INC. in 3707 WEST HARRISON ST., CHICAGO, IL 60624 (NAICS 000000). OSHA activity number 302113998.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELGIN DAIRY FOODS, INC.
- Site address
- 3707 WEST HARRISON ST.
- City
- CHICAGO
- State
- IL
- ZIP
- 60624
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2023
- Employees
- 52
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Aug 11, 1999
- Abate by
- Dec 12, 1999
- Penalty
- Initial $1,250 · Current $650 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that: a. On or about July 2, 1999, Elgin Dairy Foods had not implemented, at its plant on Harrison St., Chicago, containing refrigeration facilities, the safeguards and safety standards prescribed by the ANSI/ASHRAE Safety Code for Mechanical Refrigeration 15-1994. Thereby, the employees of Elgin Dairy Foods were exposed to releases of ammonia that might occur as a result of, but not limited to, the following: 1. In engine room #1 the south and north doors communicating with the building were not tight-fitting and piping piercing the interior walls and ceiling in engine rooms #1 and #2 was not tightly sealed to the walls and ceiling through which it passes. The south door in engine room #1 and the west door in engine room #2 both opened inward instead of outward. 2. Engine rooms #1 and #2 did not contain detectors to actuate an alarm in case of ammonia leaks. 3. Remote controls of the mechanical equipment in both engine rooms were not provided immediately outside the engine room doors. A control switch for the ventilation fan in engine room #1 was not located immediately outside that engine room door. 4.The vent line opening to atmosphere from the #2 receiver relief valve was not at least 20 feet distant from a ventilation opening to the building. The vent line opening from the common header relief piping was not at least 20 feet distant from a ventilation opening to the building. 5.Emergency shutdown procedures, including precautions to be observed in case of breakdown or leak, were not displayed on a conspicuous card posted outside each engine room, immediately adjacent to each door. 6.A schematic drawing or panel giving directions for the operation of the refrigeration system at a location convenient to the operators of the system was not provided. 7. Controls and piping involved with the refrigeration process were not provided with durable signs not less than 0.5 inches in height designating: valves or switches for controlling the refrigerant flow, the ventilation, and the refrigeration compressors, and the kind of refrigerant contained in exposed piping outside the engine room doors. 8.The size of the common relief header vent line was less than the sum of the outlet areas of the relief devices connected to it that would be expected to operate simultaneously (as in the case of a fire). 9. The maximum permissible lengths of discharge piping installed on the outlet of each pressure relief device were not determined according to formulas prescribed by ASHRAE. Feasible methods of abatement for each of the above include, but are not limited to, adherence to the safe design, construction, installation, and operation of ammonia refrigeration systems as prescribed by the ANSI/ASHRAE 15-1994 Standard (Safety Code for Mechanical Refrigeration).
Recent events (2)
- · I (S) $650.00
- · Z (S) $1250.00
More inspections at Elgin Dairy Foods, INC.
View Elgin Dairy Foods, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 302113998.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.