CUMMING, GA ·
OSHA Inspection: A. J. MULLINAX CUSTOM CABINETS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of A. J. MULLINAX CUSTOM CABINETS in 3347 BUFORD HIGHWAY, CUMMING, GA 30041 (NAICS 000000). OSHA activity number 302374475.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A. J. MULLINAX CUSTOM CABINETS
- Site address
- 3347 BUFORD HIGHWAY
- City
- CUMMING
- State
- GA
- ZIP
- 30041
- Mailing
- 3347 BUFORD HIGHWAY, CUMMINGS, GA 30041
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2434
- Employees
- 8
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- May 11, 1999
- Abate by
- Aug 10, 1999
- Penalty
- Initial $600 · Current $300 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to PVC pipes that were transporting compressed air and were not approved for that purpose. Among other methods, one feasible and acceptable abatement method to correct this hazards would be to install metal pipe to transport the compressed air. Another method would be to install the only type of plastic pipe that has been approved for use with compressed air, that pipe is Acrylonitrile-Butadiene-Styrene (ABS), this ABS marking will be labeled on the pipe. Metal piping could also replace the PVC piping in the facility.
Recent events (2)
- · I (S) $300.00
- · Z (S) $600.00
1910.213 R04
- Issued
- May 11, 1999
- Abate by
- May 21, 1999
- Penalty
- Initial $600 · Current $300 Reduced
Recent events (2)
- · I (S) $300.00
- · Z (S) $600.00
1910.213 D01
- Issued
- May 11, 1999
- Abate by
- May 21, 1999
- Penalty
- Initial $450 · Current $200 Reduced
Recent events (2)
- · I (S) $200.00
- · Z (S) $450.00
1910.213 H01
- Issued
- May 11, 1999
- Abate by
- May 21, 1999
1910.147 C01
- Issued
- May 11, 1999
- Abate by
- Aug 10, 1999
- Penalty
- Initial $600 · Current $200 Reduced
Recent events (2)
- · I (S) $200.00
- · Z (S) $600.00
1910.133 A01
- Issued
- May 11, 1999
- Abate by
- May 17, 1999
- Penalty
- Initial $450 · Current $200 Reduced
Recent events (2)
- · I (S) $200.00
- · Z (S) $450.00
1910.134 D01 II
- Issued
- May 11, 1999
- Abate by
- May 21, 1999