PASCAGOULA, MS ·
OSHA Inspection: QUAVE FABRICATION AND CONSTRUCTION CO., INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of QUAVE FABRICATION AND CONSTRUCTION CO., INC. in FIRST CHEMICAL CORP., PASCAGOULA, MS 39568 (NAICS 000000). OSHA activity number 302394861.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUAVE FABRICATION AND CONSTRUCTION CO., INC.
- Site address
- FIRST CHEMICAL CORP.
- City
- PASCAGOULA
- State
- MS
- ZIP
- 39568
- Mailing
- P. O. BOX 25, OCEAN SPRINGS, MS 39566
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1799
- Employees
- 7
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 22, 2000
- Abate by
- Jun 15, 2000
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
Section 5(a)(1) of Public Law 91-596, the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to the hazard of being struck by flying metal shrapnel and petroleum lubrication oil when on or about December 12, 1999, at First Chemical Corporation, Pascagoula, MS; Area 1400, C-1437; the portion of the Kinney Model KT-850 Vacuum Pump containing the oil observation glass exploded when compressed gas was introduced into the pump during a pneumatic leak test when: a) The vacuum pump was neither disconnected from the piping, isolated by blinds, nor a valve with a closure mechanism required during a pneumatic leak test performed on newly installed process piping for the mechanical vacuum pump. (Reference ASME B31.3, Chapter VI, Paragraph 345.3.4). Among other methods, one feasible and acceptable abatement method to correct this hszard is to assure that for future installations, equipment which is not to be tested is either disconnected from the piping, isolated by blinds, or a valve including a closure mechanism is installed in accordance with ASME B31.3-1996, Process Piping, an American National Standard.