MIDDLE FALLS, NY —
OSHA Inspection: AMERICAN TISSUE MILLS OF GREENWICH, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AMERICAN TISSUE MILLS OF GREENWICH, LLC in 192 COUNTY RTE. 53, MIDDLE FALLS, NY 12848 (NAICS 000000). OSHA activity number 302554431.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN TISSUE MILLS OF GREENWICH, LLC
- Site address
- 192 COUNTY RTE. 53
- City
- MIDDLE FALLS
- State
- NY
- ZIP
- 12848
- Mailing
- P.O. BOX 30, GREENWICH, NY 12834
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2621
- Employees
- 63
- Ownership type
- A
Citations
26 citations on file for this inspection.
5(a)(1)
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to decapitation/amputation by being struck by a moving elevator car due to a lack of adequate hoistway doors; and/or exposed to amputation/crushing by being caught in the shear point between the elevator car and the hoistway due to a lack of elevator car gates; and/or falling down an elevator shaft due to a lack of electrical interlocks on the hoistway doors to prevent them from being opened when the elevator car is not in the landing zone; and/or lack of see through panels through which one can tell whether or not the elevator is in the landing zone; and/or amputation/crushing due to a lack of parking devices to ensure the elevator cars will stop only at floor level; and/or inability to get help if needed in an emergency due to lack of an emergency signaling device; and/or the increased potential of injury due to an elevator having only one available light, should that light go out or break; and/or riding/using unsafe elevators that had not been approved for operation due to not being subjected to inspections a minimum of every six months: a)Maintenance Elevator - Cohoes Iron Works elevator used to carry employees and equipment: - Elevator car was not equipped with interlocked car gates in accordance with American National Standards Institute (ANSI) Standard A17.3, paragraph 3.4.2. - Hoistway doors on first and second floors were not equipped with hoistway door unlocking devices/hoistway access switches (interlocks) to prevent the opening of the doors when the elevator car is not in the landing zone, in accordance with ANSI Standard A17.3, paragraph 2.7.3. - Hoistway doors did not have vision panels not less than 25 square inches and not more than 80 square inches, in accordance with ANSI Standard A17.3, paragraph 2.6.3. - Elevator was not equipped with a parking device to prevent the doors from opening unless the elevator is in line with the landing zone, in accordance with ANSI Standard A17.3, paragraph 2.7.2. - Elevator was not equipped with an emergency signaling device (alarm) in accordance with ANSI Standard A17.3, paragraph 3.11.1. - Elevator was not equipped with a minimum of two lamps in accordance with ANSI A17.3, paragraph 3.4.5. - Elevator had never been inspected, as required, a minimum of every six months in accordance with ANSI Standard A17.1, Section 1001.1 b) Machine Room #3 - Craig Ridgway elevator used for lifting freight only: - First floor front and rear hoistway doors, which were 48 3/4" high, did not meet the minimum 6' requirement in accordance with ANSI Standard A17.3, paragraph 2.6.1(b). - Second floor hoistway door which was 48 3/4" high did not meet the minimum 6' height requirement in accordance with ANSI Standard A17.3, paragraph 2.6.1(b). - Hoistway doors were not equipped with hoistway door unlocking devices/hoistway access switches (interlocks) to prevent the opening of the doors when the elevator car is not in the landing zone, in accordance with ANSI Standard A17.3, paragraph 2.6.3. - Elevator had never been inspected, as required, a minimum of every six months in accordance with ANSI Standard A17.1, Section 1001.1. c. Old Converting Plant - Otis elevator used for lifting freight only: - Hoistway doors did not have vision panels not less than 25 square inches and not more than 80 square inches in accordance with ANSI Standard 2.6.3. - Elevator had never been inspected, as required, a minimum of every six months in accordance with ANSI Standard A17.1, Section 1001.1. One feasible method of abatement is to install adequate hoistway doors, install elevator car gates, install hoistway door and elevator gate unlocking devices/access switches, install vision panels, install parking devices, install an emergency signaling system, install a second lamp, and have elevators inspected a minimum of every six months. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — F (S) $3500.00
- — Z (S) $7000.00
1910.22 D01
- Issued
- May 16, 2000
- Abate by
- Aug 31, 2001
- Penalty
- Initial $2,500 · Current $1,250 Reduced
Recent events (3)
- — F (S) $1250.00
- — P (S) $2500.00
- — Z (S) $2500.00
1910.23 C03
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $2,500 · Current $1,250 Reduced
Recent events (2)
- — F (S) $1250.00
- — Z (S) $2500.00
1910.36 B07
- Issued
- May 16, 2000
- Abate by
- Aug 31, 2001
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (3)
- — F (S) $750.00
- — P (S) $1500.00
- — Z (S) $1500.00
1910.132 A
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $2,000 · Current $1,000 Reduced
Recent events (2)
- — F (S) $1000.00
- — Z (S) $2000.00
1910.151 C
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $2,000 · Current $1,000 Reduced
Recent events (2)
- — F (S) $1000.00
- — Z (S) $2000.00
1910.179 L03 I
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $7,000 · Current $3,500 Reduced
Recent events (2)
- — F (S) $3500.00
- — Z (S) $7000.00
1910.212 A05
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $2,500 · Current $1,250 Reduced
Recent events (2)
- — F (S) $1250.00
- — Z (S) $2500.00
1910.219 D01
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $2,500 · Current $1,250 Reduced
Recent events (2)
- — F (S) $1250.00
- — Z (S) $2500.00
1910.219 E01 I
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
Recent events (2)
- — F (S)
- — Z (S)
1910.261 B02
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- — F (S) $750.00
- — Z (S) $1500.00
1910.261 J05 II
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $2,500 · Current $1,250 Reduced
Recent events (2)
- — F (S) $1250.00
- — Z (S) $2500.00
1910.261 J05 III
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $2,500 · Current $1,250 Reduced
Recent events (2)
- — F (S) $1250.00
- — Z (S) $2500.00
1910.261 J06 I
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
Recent events (2)
- — F (S)
- — Z (S)
1910.261 K02 III
- Issued
- May 16, 2000
- Abate by
- Aug 31, 2001
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (3)
- — F (S) $750.00
- — P (S) $1500.00
- — Z (S) $1500.00
1910.305 B01
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $2,500 · Current $1,250 Reduced
Recent events (2)
- — F (S) $1250.00
- — Z (S) $2500.00
1910.305 J02 II
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- — F (S) $750.00
- — Z (S) $1500.00
1910.261 K26 I
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $7,000 · Current $3,500 Reduced
Recent events (2)
- — F (S) $3500.00
- — Z (S) $7000.00
1910.179 J02
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $25,000 · Current $12,500 Reduced
Recent events (2)
- — F (R) $12500.00
- — Z (R) $25000.00
1910.179 M01
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
Recent events (2)
- — F (R)
- — Z (R)
1910.212 A01
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
- Penalty
- Initial $25,000 · Current $12,500 Reduced
Recent events (2)
- — F (R) $12500.00
- — Z (R) $25000.00
1910.261 K10
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
Recent events (2)
- — F (R)
- — Z (R)
1910.22 A03
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
Recent events (2)
- — F (O)
- — Z (O)
1910.24 H
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
Recent events (2)
- — F (O)
- — Z (O)
1910.254 D09 III
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
Recent events (2)
- — F (O)
- — Z (O)
1910.305 G01 IIIA
- Issued
- May 16, 2000
- Abate by
- Jun 18, 2000
Recent events (2)
- — F (O)
- — Z (O)
More inspections at American Tissue Mills of Greenwich, LLC
View American Tissue Mills of Greenwich, LLC's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 302554431.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.