Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN TISSUE MILLS OF GREENWICH, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERICAN TISSUE MILLS OF GREENWICH, LLC in 192 COUNTY RTE. 53, MIDDLE FALLS, NY 12848 (NAICS 000000). OSHA activity number 302554431.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Tissue Mills of Greenwich, LLC — free Get an email when a new federal OSHA severe-injury report for American Tissue Mills of Greenwich, LLC is published. One employer, no account, unsubscribe in one click.
Site address
192 COUNTY RTE. 53
City
MIDDLE FALLS
State
NY
ZIP
12848
Mailing
P.O. BOX 30, GREENWICH, NY 12834
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
2621
Employees
63
Ownership type
A

26 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 16 instances 7 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $7,000 · Current $3,500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to decapitation/amputation by being struck by a moving
elevator car due to a lack
of adequate hoistway doors; and/or exposed to amputation/crushing by being
caught in the shear
point between the elevator car and the hoistway due to a lack of elevator
car gates; and/or falling
down an elevator shaft due to a lack of electrical interlocks on the
hoistway doors to prevent
them from being opened when the elevator car is not in the landing zone;
and/or lack of see
through panels through which one can tell whether or not the elevator is
in the landing zone;
and/or amputation/crushing due to a lack of parking devices to ensure the
elevator cars will stop
only at floor level; and/or inability to get help if needed in an
emergency due to lack of an
emergency signaling device; and/or the increased potential of injury due
to
an elevator having
only one available light, should that light go out or break; and/or
riding/using unsafe elevators
that had not been approved for operation due to not being subjected to
inspections a minimum
of every six months:
a)Maintenance Elevator - Cohoes Iron Works elevator used to carry
employees and
equipment:
- Elevator car was not equipped with interlocked car gates in accordance
with
American National Standards Institute (ANSI) Standard A17.3, paragraph
3.4.2.
- Hoistway doors on first and second floors were not equipped with
hoistway door
unlocking devices/hoistway access switches (interlocks) to prevent the
opening of
the doors when the elevator car is not in the landing zone, in accordance
with
ANSI Standard A17.3, paragraph 2.7.3.
- Hoistway doors did not have vision panels not less than 25 square inches
and
not more than 80 square inches, in accordance with ANSI Standard A17.3,
paragraph 2.6.3.
- Elevator was not equipped with a parking device to prevent the doors from
opening unless the elevator is in line with the landing zone, in
accordance with
ANSI Standard A17.3, paragraph 2.7.2.
- Elevator was not equipped with an emergency signaling device (alarm) in
accordance with ANSI Standard A17.3, paragraph 3.11.1.
- Elevator was not equipped with a minimum of two lamps in accordance with
ANSI A17.3, paragraph 3.4.5.
- Elevator had never been inspected, as required, a minimum of every six
months
in accordance with ANSI Standard A17.1, Section 1001.1
b)  Machine Room #3 - Craig Ridgway elevator used for lifting freight only:
- First floor front and rear hoistway doors, which were 48 3/4" high, did
not
meet the minimum 6' requirement in accordance with ANSI Standard A17.3,
paragraph 2.6.1(b).
- Second floor hoistway door which was 48 3/4" high did not meet the
minimum
6' height requirement in accordance with ANSI Standard A17.3, paragraph
2.6.1(b).
- Hoistway doors were not equipped with hoistway door unlocking
devices/hoistway access switches (interlocks) to prevent the opening of
the  doors
when the elevator car is not in the landing zone, in accordance with ANSI
Standard A17.3, paragraph 2.6.3.
- Elevator had never been inspected, as required, a minimum of every six
months
in accordance with ANSI Standard A17.1, Section 1001.1.
c.  Old Converting Plant - Otis elevator used for lifting freight only:
- Hoistway doors did not have vision panels not less than 25 square inches
and
not more than 80 square inches in accordance with ANSI Standard 2.6.3.
- Elevator had never been inspected, as required, a minimum of every six
months
in accordance with ANSI Standard A17.1, Section 1001.1.
One feasible method of abatement is to install adequate hoistway doors,
install
elevator car gates, install hoistway door and elevator gate unlocking
devices/access switches, install vision panels, install parking devices,
install an
emergency signaling system, install a second lamp, and have elevators
inspected
a minimum of every six months.
ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
  • — F (S) $3500.00
  • — Z (S) $7000.00

1910.22 D01

Serious Gravity 03 1 instance 39 exposed
Issued
May 16, 2000
Abate by
Aug 31, 2001
Penalty
Initial $2,500 · Current $1,250 Reduced
Recent events (3)
  • — F (S) $1250.00
  • — P (S) $2500.00
  • — Z (S) $2500.00

1910.23 C03

Serious Gravity 03 5 instances 9 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $2,500 · Current $1,250 Reduced
Recent events (2)
  • — F (S) $1250.00
  • — Z (S) $2500.00

1910.36 B07

Serious Gravity 01 3 instances 63 exposed
Issued
May 16, 2000
Abate by
Aug 31, 2001
Penalty
Initial $1,500 · Current $750 Reduced
Recent events (3)
  • — F (S) $750.00
  • — P (S) $1500.00
  • — Z (S) $1500.00

1910.132 A

Serious Gravity 02 2 instances 11 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $2,000 · Current $1,000 Reduced
Recent events (2)
  • — F (S) $1000.00
  • — Z (S) $2000.00

1910.151 C

Serious Gravity 02 3 instances 11 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $2,000 · Current $1,000 Reduced
Recent events (2)
  • — F (S) $1000.00
  • — Z (S) $2000.00

1910.179 L03 I

Serious Gravity 10 4 instances 18 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $7,000 · Current $3,500 Reduced
Recent events (2)
  • — F (S) $3500.00
  • — Z (S) $7000.00

1910.212 A05

Serious Gravity 03 1 instance 9 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $2,500 · Current $1,250 Reduced
Recent events (2)
  • — F (S) $1250.00
  • — Z (S) $2500.00

1910.219 D01

Serious Gravity 03 2 instances 13 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $2,500 · Current $1,250 Reduced
Recent events (2)
  • — F (S) $1250.00
  • — Z (S) $2500.00

1910.219 E01 I

Serious Gravity 03 2 instances 13 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Recent events (2)
  • — F (S)
  • — Z (S)

1910.261 B02

Serious Gravity 01 1 instance 63 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $1,500 · Current $750 Reduced
Recent events (2)
  • — F (S) $750.00
  • — Z (S) $1500.00

1910.261 J05 II

Serious Gravity 03 2 instances 8 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $2,500 · Current $1,250 Reduced
Recent events (2)
  • — F (S) $1250.00
  • — Z (S) $2500.00

1910.261 J05 III

Serious Gravity 03 2 instances 8 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $2,500 · Current $1,250 Reduced
Recent events (2)
  • — F (S) $1250.00
  • — Z (S) $2500.00

1910.261 J06 I

Serious Gravity 03 1 instance 8 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Recent events (2)
  • — F (S)
  • — Z (S)

1910.261 K02 III

Serious Gravity 01 3 instances 9 exposed
Issued
May 16, 2000
Abate by
Aug 31, 2001
Penalty
Initial $1,500 · Current $750 Reduced
Recent events (3)
  • — F (S) $750.00
  • — P (S) $1500.00
  • — Z (S) $1500.00

1910.305 B01

Serious Gravity 03 4 instances 7 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $2,500 · Current $1,250 Reduced
Recent events (2)
  • — F (S) $1250.00
  • — Z (S) $2500.00

1910.305 J02 II

Serious Gravity 01 2 instances 8 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $1,500 · Current $750 Reduced
Recent events (2)
  • — F (S) $750.00
  • — Z (S) $1500.00

1910.261 K26 I

Serious Gravity 10 3 instances 9 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $7,000 · Current $3,500 Reduced
Recent events (2)
  • — F (S) $3500.00
  • — Z (S) $7000.00

1910.179 J02

Repeat Gravity 10 4 instances 18 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $25,000 · Current $12,500 Reduced
Recent events (2)
  • — F (R) $12500.00
  • — Z (R) $25000.00

1910.179 M01

Repeat Gravity 10 4 instances 18 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Recent events (2)
  • — F (R)
  • — Z (R)

1910.212 A01

Repeat Gravity 10 3 instances 17 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Penalty
Initial $25,000 · Current $12,500 Reduced
Recent events (2)
  • — F (R) $12500.00
  • — Z (R) $25000.00

1910.261 K10

Repeat Gravity 10 2 instances 9 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Recent events (2)
  • — F (R)
  • — Z (R)

1910.22 A03

Other-than-serious Gravity 01 2 instances 63 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Recent events (2)
  • — F (O)
  • — Z (O)

1910.24 H

Other-than-serious Gravity 01 2 instances 15 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Recent events (2)
  • — F (O)
  • — Z (O)

1910.254 D09 III

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Recent events (2)
  • — F (O)
  • — Z (O)

1910.305 G01 IIIA

Other-than-serious Gravity 01 1 instance 8 exposed
Issued
May 16, 2000
Abate by
Jun 18, 2000
Recent events (2)
  • — F (O)
  • — Z (O)

View American Tissue Mills of Greenwich, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 302554431.