Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: QUALITY FRAMING INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of QUALITY FRAMING INC. in 130 HOWARD LANE, FAYETTEVILLE, GA 30215 (NAICS 000000). OSHA activity number 302560859.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Framing INC. for free Get an email when a new federal OSHA severe-injury report for Quality Framing INC. is published. One employer, no account, unsubscribe in one click.
Site address
130 HOWARD LANE
City
FAYETTEVILLE
State
GA
ZIP
30215
Mailing
798 SCOTT LANE, MARIETTA, GA 30060
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1751
Employees
5
Ownership type
Private (A)
Industry flags
Construction safety.

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
May 22, 2000
Abate by
Jun 2, 2000
Penalty
Initial $5,600 · Current $5,600
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish to each of his employees employment and a place of employment
which were free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees in that employees were exposed to: in that employees were
exposed to falls from
elevation and/or crushing injuries from the collapse of improper temporary
bracing of wooden
roof trusses.
(1) Construction site of office building 6 on Howard Lane in Fayetteville,
Georgia:
Workers setting and installing thirty 43' span metal plate connected wood
trusses on a
commercial building, were exposed to the hazard of collapsing trusses due
to insufficient
bracing. On or about December 29,1999.
Among other methods, three feasible and acceptable abatement methods to
correct this
hazard is to:
(1). Provide adequate training to ensure that each employee acquires the
knowledge and
skills of truss erection so that they understand how to correctly set and
install temporary
bracing safely on metal plate connected wood trusses.
(2). Ensure that each employee follows the practices for safe installation
of wood roof
trusses detailed in the HIB-91, Commentary and Recommendation for Handling,
Installing, and Bracing Metal Plate Connected Wood Trusses, before the
erection begins.
(3). Provide and post a copy of the truss warning poster on the site.
ABATEMENT DOCUMENTATION AND CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $5600.00
  • · Z (S) $5600.00

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
May 22, 2000
Abate by
Jun 2, 2000
Penalty
Initial $4,000 · Current $600 Reduced
Recent events (2)
  • · I (S) $600.00
  • · Z (S) $4000.00

1926.21 B02

Serious Gravity 05 1 instance 5 exposed
Issued
May 22, 2000
Abate by
Jun 9, 2000
Penalty
Initial $2,800 · Current $600 Reduced
Recent events (2)
  • · I (S) $600.00
  • · Z (S) $2800.00

View Quality Framing INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 302560859.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.