IDAHO FALLS, ID ·
OSHA Inspection: D. W. POWER INDUSTRIAL COATINGS
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of D. W. POWER INDUSTRIAL COATINGS in 1300 PANCHERI DRIVE, IDAHO FALLS, ID 83401 (NAICS 000000). OSHA activity number 302583208.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D. W. POWER INDUSTRIAL COATINGS
- Site address
- 1300 PANCHERI DRIVE
- City
- IDAHO FALLS
- State
- ID
- ZIP
- 83401
- Mailing
- P.O. BOX 151, ARCO, ID 83213
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1721
- Employees
- 1
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.106 E06 I
- Issued
- Dec 8, 1999
- Abate by
- Dec 14, 1999
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · F (S) $375.00
- · Z (S) $750.00
1910.307 B
- Issued
- Dec 8, 1999
- Abate by
- Dec 14, 1999
Recent events (2)
- · F (S)
- · Z (S)
1910.134 C01
- Issued
- Dec 8, 1999
- Abate by
- Jan 5, 2000
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · F (S) $375.00
- · Z (S) $750.00
1910.134 E01
- Issued
- Dec 8, 1999
- Abate by
- Jan 5, 2000
Recent events (2)
- · F (S)
- · Z (S)
5(a)(1)
- Issued
- Dec 8, 1999
- Abate by
- Dec 14, 1999
General-duty citation text
29 CFR 1910.134(i)(5)(iii): The employer did not provide breathing air compressors with in- line air-purifying sorbent beds and filters: (a)American Fabrication Spray Area - On or about 2 December 1999, and at times prior thereto, the Coleman Power Mate compressor (serial # W3280457/model # CL0502713) was not equipped with in-line air-purifying sorbent beds and filters to ensure breathing air quality. Note: Abatement certification and supporting documentation are required for this item.
Recent events (2)
- · F (S)
- · Z (S)
5(a)(1)
- Issued
- Dec 8, 1999
- Abate by
- Dec 14, 1999
General-duty citation text
29 CFR 1910.134(i)(7): The employer did not provide high-temperature or carbon monoxide alarms (or both), for oil-lubricated compressors, used to provided breathing air for in-line air-purifying respirators: (a)American Fabrication Spray Area - On or about 2 December 1999, and at times prior thereto, the Coleman Power Mate compressor (serial # W3280457/model # CL0502713) was not equipped with a high-temperature or carbon monoxide alarms to prevent carbon monoxide in the breathing air from exceeding 10 parts-per-million (ppm). Note: Abatement certification and supporting documentation are required for this item.
Recent events (2)
- · F (S)
- · Z (S)
1910.219 D01
- Issued
- Dec 8, 1999
- Abate by
- Dec 14, 1999
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · F (S) $375.00
- · Z (S) $750.00
1910.219 E01 I
- Issued
- Dec 8, 1999
- Abate by
- Dec 14, 1999
Recent events (2)
- · F (S)
- · Z (S)
More inspections in this industry (NAICS 000000)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 302583208.