IDAHO FALLS, ID —
OSHA Inspection: STEEL SYSTEMS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STEEL SYSTEMS, INC. in 5296 S. HEYREND DRIVE, IDAHO FALLS, ID 83401 (NAICS 000000). OSHA activity number 302583216.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STEEL SYSTEMS, INC.
- Site address
- 5296 S. HEYREND DRIVE
- City
- IDAHO FALLS
- State
- ID
- ZIP
- 83401
- Mailing
- P.O. BOX 50213, IDAHO FALLS, ID 83405
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1541
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 7, 1999
- Abate by
- Dec 13, 1999
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of structural collapse: (a)5296 S. Heyrend Drive, Idaho Falls, ID - On or about November 24, 1999, and at times prior thereto, the building under construction was not adequately braced to prevent collapse. "AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO FOLLOW THE GUIDANCE PROVIDE BY THE TRUSS PLATE INSTITUTE HANDBOOK - RECOMMENDED DESIGN SPECIFICATION FOR TEMPORARY BRACING OF METAL PLATE CONNECTED WOOD TRUSSES (DSB-89) AND THE COMMENTARY AND RECOMMENDATION FOR HANDLING INSTALLING AND BRACING METAL PLATE CONNECTED WOOD TRUSSES (HIB-91). IN ADDITION, ATTACH WOOD COLUMN/POST TO STANDOFF POST BASE PER MANUFACTURER'S SPECIFICATION. SIMPSON STRONG-TIE CATALOG C- 99, PAGE 5, GENERAL NOTES, PARAGRAPH h STATES THROUGH BOLTS MUST BE USED THAT ARE EQUAL TO OR BETTER THAN ASTM STANDARD A 307, GRADE A; PAGE 26 FOR A CBS44 STANDOFF BASE REQUIRES A 5/8 INCH DIAMETER THROUGH BOLT. LAG BOLTS MAY NOT BE USED IN PLACE OF THROUGH BOLTS, PER MANUFACTURER". Note: Abatement certification and supporting documentation are required for this item.
1926.95 A
- Issued
- Dec 7, 1999
- Abate by
- Dec 13, 1999
- Penalty
- Initial $750 · Current $750
1926.451 G04 I
- Issued
- Dec 7, 1999
- Abate by
- Dec 13, 1999
- Penalty
- Initial $750 · Current $750
1926.300 B02
- Issued
- Dec 7, 1999
- Abate by
- Dec 13, 1999
- Penalty
- Initial $750 · Current $750
More inspections at Steel Systems, INC.
View Steel Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 302583216.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.