Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WIREWAY/HUSKY CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WIREWAY/HUSKY CORP. in 6146 DENVER INDUSTRIAL PARK, DENVER, NC 28037 (NAICS 000000). OSHA activity number 302651534.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wireway/Husky Corp. — free Get an email when a new federal OSHA severe-injury report for Wireway/Husky Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
WIREWAY/HUSKY CORP.
Site address
6146 DENVER INDUSTRIAL PARK
City
DENVER
State
NC
ZIP
28037
Mailing
P.O. BOX 645, DENVER, NC 28037
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
3449
Employees
204
Ownership type
A
Industry flags
Manufacturing safety.

12 citations on file for this inspection.

95012901

Serious 2 instances 1 exposed
Issued
May 14, 1999
Abate by
Jun 1, 1999
Penalty
Initial $613 · Current $613
North Carolina General Statute 95-129(1) of the Occupational Safety
and Health Act of North Carolina:  The employer did not furnish to
each of his employees conditions of employment and a place of
employment which were free from recognized hazards that were
causing or likely to cause death or serious physical harm to
employees:
a) facility; press area - underhung crane with CM Lodestar
hoist has not been load tested.
b)facility; parts cleaner - underhung crane with Jet hoist
has not been load tested.
Reference: ANSI B30.11-1980; Paragraph 11-2.2.2(a) Rated load
test - Prior to initial use, all new, extensively repaired,
and altered equipment should be tested...
NOTE: Among other methods, one feasible and acceptable method
to correct this hazard is to conduct the load test and have
test reports readily available.

1910.179 K02

Serious 1 instance 1 exposed
Issued
May 14, 1999
Abate by
Jun 1, 1999

1910.133 A01

Serious 1 instance 1 exposed
Issued
May 14, 1999
Abate by
May 19, 1999
Penalty
Initial $438
Recent events (2)
  • — I (S)
  • — Z (S) $438.00

1910.38 A01

Other-than-serious 1 instance 1 exposed
Issued
May 14, 1999
Abate by
May 22, 1999

1910.147 C04 I

Other-than-serious 1 instance 1 exposed
Issued
May 14, 1999
Abate by
May 22, 1999

1910.215 A04

Other-than-serious 1 instance 1 exposed
Issued
May 14, 1999
Abate by
May 22, 1999

1910.253 B02 II

Other-than-serious 1 instance 1 exposed
Issued
May 14, 1999
Abate by
May 22, 1999

1910.253 B02 IV

Other-than-serious 1 instance 1 exposed
Issued
May 14, 1999
Abate by
May 22, 1999

1910.253 B04 III

Other-than-serious 1 instance 1 exposed
Issued
May 14, 1999
Abate by
May 22, 1999

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
May 14, 1999
Abate by
May 22, 1999

1910.213 I01

Other-than-serious 1 instance 1 exposed
Issued
May 14, 1999
Abate by
May 22, 1999

1910.304 F04

Serious 2 instances 1 exposed
Issued
May 10, 1999
Abate by
May 20, 1999
Penalty
Initial $613 · Current $613

View Wireway/Husky Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 302651534.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.