GASTONIA, NC ·
OSHA Inspection: R.W.M. CASTERS COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of R.W.M. CASTERS COMPANY in 1225 ISLEY ROAD, GASTONIA, NC 28053 (NAICS 000000). OSHA activity number 302652508.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R.W.M. CASTERS COMPANY
- Site address
- 1225 ISLEY ROAD
- City
- GASTONIA
- State
- NC
- ZIP
- 28053
- Mailing
- P.O. BOX 668, GASTONIA, NC 28053
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3429
- Employees
- 103
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
11 citations on file for this inspection.
95012901
- Issued
- May 26, 1999
- Abate by
- Jun 8, 1999
- Penalty
- Initial $438 · Current $438
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a)facility; tool/die - monorail system with Budgit 1/2 hoist has not been load tested. b)facility; dip tank area - monorail system with CM Valuestar hoist has not been load tested. c) facility; welding - the structure of floor mounted jib crane has not been inspected. d)facility; heavy duty assembly - underhung crane system with 1 ton Budgit hoist has not been load tested. e)facility; machine shop - underhung crane system with 1/2 ton Coffing hoist has not been load tested. REFERENCE: ANSI B30.11 - 1980; paragraph 11.2.2.2(a) Rated load test - Prior tio initial use, all the equipment mentioned in the above paragraph is to be load tested. NOTE: Among other methods, one feasible and acceptable measure of control is to have load tests conducted.
1910.212 A03 II
- Issued
- May 26, 1999
- Abate by
- Jun 14, 1999
- Penalty
- Initial $313 · Current $313
1910.213 I01
- Issued
- May 26, 1999
- Abate by
- Jun 3, 1999
- Penalty
- Initial $313 · Current $313
1910.215 B09
- Issued
- May 26, 1999
- Abate by
- Jun 3, 1999
- Penalty
- Initial $625 · Current $625
1910.215 A04
- Issued
- May 26, 1999
- Abate by
- Jun 3, 1999
1910.304 F05 V
- Issued
- May 26, 1999
- Abate by
- Jun 3, 1999
- Penalty
- Initial $438 · Current $438
1910.147 C04 I
- Issued
- May 26, 1999
- Abate by
- Jun 3, 1999
1910.304 F04
- Issued
- May 26, 1999
- Abate by
- Jun 3, 1999
1910.305 B01
- Issued
- May 26, 1999
- Abate by
- Jun 3, 1999
1910.1200 F05 I
- Issued
- May 26, 1999
- Abate by
- Jun 3, 1999
1910.1200 H
- Issued
- May 26, 1999
- Abate by
- Jun 3, 1999