CAMILLUS, NY ·
OSHA Inspection: CAMILLUS CUTLERY COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CAMILLUS CUTLERY COMPANY in 54 MAIN STREET, CAMILLUS, NY 13031 (NAICS 000000). OSHA activity number 302693700.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAMILLUS CUTLERY COMPANY
- Site address
- 54 MAIN STREET
- City
- CAMILLUS
- State
- NY
- ZIP
- 13031
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3421
- Employees
- 155
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 12, 2001
- Abate by
- Feb 14, 2001
- Penalty
- Initial $1,100 · Current $1,100
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to THE HAZARD OF BEING CAUGHT-IN THE HOISTWAY OBSTRUCTIONS OF A MOVING ELEVATOR: a)Freight elevator, on or about 01/04/01: The gates on the front and back of the freight elevator had openings 4-inches by 9-inches. ABATEMENT NOTES: Among other methods, one feasible and acceptable methods to abate these hazards is to: Construct guards that have openings not larger than 3-inches in diameter, in accordance with ASME A17.3a-1989.
Recent events (2)
- · I (S) $1100.00
- · Z (S) $1100.00
5(a)(1)
- Issued
- Jan 12, 2001
- Abate by
- Jan 18, 2001
- Penalty
- Initial $1,100 · Current $715 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to THE HAZARD OF BEING STRUCK-BY THE LOAD SHOULD THE OVERHEAD HOIST, SUPPORTING STRUCTURE, OR BELOW THE HOOK LIFTING DEVICE FAIL: a)On or about 12/07/00: The following overhead hoists had improperly rated structures, below the hook lifting devices that were not rated, and frequent and periodic inspections were not being completed. 1. Press room, 4000 lb Coffing hoist used on a structure rated at 1000 lbs, two below the hook lifting devices without rated load capacity markings and no inspections were performed. 2. Heat treat area, 2000 lb Coffing hoist used on a structure rated at 1000 lbs. 3. Barrel room, 2000 lb Coffing hoist used on a structure rated at 1000 lbs. ABATEMENT NOTES: Among other methods, one feasible and acceptable methods to abate these hazards is to: Conduct initial, frequent and periodic inspections of the hoists and support structures for wear, deterioration, or malfunction in accordance with ASME B30.16-1987 and ASME B30.20-1985.
Recent events (2)
- · I (S) $715.00
- · Z (S) $1100.00
1910.212 A01
- Issued
- Jan 12, 2001
- Abate by
- Feb 28, 2001
- Penalty
- Initial $1,100 · Current $715 Reduced
Recent events (2)
- · I (S) $715.00
- · Z (S) $1100.00
1910.212 A03 II
- Issued
- Jan 12, 2001
- Abate by
- Jan 18, 2001
- Penalty
- Initial $1,100 · Current $715 Reduced
Recent events (2)
- · I (S) $715.00
- · Z (S) $1100.00
1910.212 A05
- Issued
- Jan 12, 2001
- Abate by
- Jan 18, 2001
- Penalty
- Initial $1,100 · Current $715 Reduced
Recent events (2)
- · I (S) $715.00
- · Z (S) $1100.00
More inspections at Camillus Cutlery Company
View Camillus Cutlery Company's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 302693700.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.